Electric wiring
1. All field supplied parts and materials must conform to local laws and regulations.
2. For electric wiring, refer to WIRING DIAGRAM attached to the unit body.
3. All wiring must be performed by a skilled technician.
4. A circuit breaker capable of shutting down power supply to the entire system and which have at least
3 mm contact separation in each jole must be install in the fixed wiring.
5. Earth properly.
6. Wiring must conform to national laws and regulations.
7. The fixed wiring must be installed with a protector with no more that 30 mA leakage current.
8. If the supply cord is damaged, it must be replaced by the manufacturer or its appointed service agents
in order to avoid a hazard.
• Wiring of unit and the controller
1. Wiring of the indoor unit.
Remove the control box lid, pull the wires inside through rubber bush and wiring according to the
WIRING DIAGRAM , then tighten it with clamp.
2. Wiring of the controller
1) Remove the control box lid, pull wires inside through rubber bush and connect to the controller.
2) Wrap the wire with sealing pad.
3) After wiring, tighten it with clamp and fix the control box lid.
Electrical box
Stopper(metal)
Power source wiring
Transmission wiring
Remote control switch cable
• Precautions: Be sure to connect the indoor unit and outdoor unit at right poles.
Clamp
Screw
Printed Circuit Board
Power source wiring
Operating wiring
Remote control switch cable
Hole for wiring connection Ø 32.5(for spare)
(Knock-out hole)
Hole for wiring connection 30x39
(for cable)
Leaf motor connection
Wire remote control
connection(Optional
components)
Transmission wiring
32
Power sourcing wiring