4.2.5.

Configuration Notes

Depending on the type of SIM used and the slot in which this is installed, there are interfaces
available on the front of the housing. Which of these interfaces is assigned to which SIM and
in which slot the associated patch plug must be plugged in is shown in the following table:
SIM-Type
SM-2551 (SIP)
SM-2558 (NIP)
SM-2557 (NIP)
SM-2545 (FIP)
SM-0551 (SIP)
1)
SM-0551 must be mounted on SM-2558
2)
Due to thermal rasons only one SM-2545 (on SIM1) may be equipped
SICAM TM, Installation
DC6-015-2.04, Edition 10.2014
Slot
Interfaces on Front of
SIM0
SI0
SIM1
SIM0
SIM1
SIM0
SI0
SIM1
2)
SIM1
1)
1)
SIM0
SI0
Slots for Patch Plugs on
Housing
SI1
X24
SI2
SI3
SI1
SI3
SI1
X24
SI2
SI3
SI2
SI2
X24
Wiring Communication
Main Board
X25
X26
X27
X25
X27
X25
X26
X27
X26
X26