10. Hook the new control unit into the cabinet and hold it with one
hand.
11. Mount all holders of the control unit and tighten the screws.
– Torque = 1.0 ±0.1 Nm
Torque [Nm]
1.0 ±0.1
12. Insert the SIM card.
13. Screw the antenna cable plug to the CIM card antenna
connection at the control unit.
1
2
14. Plug in all connectors at the control unit.
15. Note the IMEI number of the new control unit.
16. Complete the internal servicing of the AQtap, see section
17.14 Completing steps after internal servicing.
17. Update the Water Management System with the new IMEI
number.