Installer Settings

RF Pairing
Control Type This allows the thermostat to be set to run in On/
Start-up
Method
Danfoss Heating
The TPOne-RF must be paired to a compatible
receiver/boiler relay. The initial pairing is made
in the startup wizard. If pairing was not made at
startup or if pairing is required to a new receiver/
boiler relay select this setting to start new pairing.
Off mode or in chrono-proportional 3, 6 or 12
cycle rate.
Default: Chrono 6
Note: for condensing boiler control tests have
shown that boiler efficiency is significantly
improved when controlled by a chrono-
proportional type controller
This feature allows the thermostat to start up the
heating system in three different ways.
Normal - Heating is turned up or down at the
programmed times.
Delayed start (or Economy Setting) -
Set the period start times in the normal way
taking into account the time that the building
takes to heat on an average day. The thermostat
monitors switch on time, actual temperature and
wanted temperature and delays the start of the
heating if the actual temperature is close to the
programmed temperature. Delayed Start in TPOne
is dynamic and will adjust automatically to the
home heating characteristics while maximising
energy savings.
Optimised Start (or Comfort Setting) -
This allows you to programme the time at
which you would like to be up to the required
temperature. The thermostat then calculates
how soon before the required time the heating is
turned up. Optimised Start in TPOne is dynamic
and will adjust automatically to the home heating
characteristics to reach required temperature at
the required time.
Default: Normal