Danfoss TP7001 Range Installation Manual

Danfoss TP7001 Range Installation Manual

Electronic 7 day programmable room thermostat
Hide thumbs Also See for TP7001 Range:

Advertisement

TP7001 Range
Electronic 7 Day
Programmable Room Thermostat
Installation Guide
Danfoss Heating

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss TP7001 Range

  • Page 1 TP7001 Range Electronic 7 Day Programmable Room Thermostat Installation Guide Danfoss Heating...
  • Page 2 Marketing on 0845 121 7400. Certification Mark Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
  • Page 3: Table Of Contents

    Installation Instructions TP7001 Range Electronic Programmable Room Thermostat Index Installation Guide ................4 System Overview .................4 Installation ....................5 3.1 Removing the wallplate .............5 3.2 Installation considerations ............5 3.3 Affi xing the backplate ..............5 3.4 Wiring ....................6 3.5 Batteries ...................6 3.6 Tamperproof operation ..............7 3.7 Mounting the unit ................7...
  • Page 4: Installation Guide

    1.0 Installation Guide Please Note: This product should only be installed by a qualifi ed electrician or competent heating installer and should be in accordance with the current edition of the IEEE wiring regulations. 2.0 System Overview Thermostat Features TP7001 TP7001M 2 x AA/MN1500/LR6 Power supply...
  • Page 5: Installation

    106mm below in order to mount the plug-in module. 3.3 Fix the TP70001/TP7001M and its optional remote room sensor at a height of approximately 1.5m from the fl oor, away from draughts or heat sources such as radiators, open fi res or direct sunlight. Danfoss Heating...
  • Page 6: Wiring

    3.4 For wiring connections please refer to the diagrams below: Battery Version Room/outdoor/limit sensor or contact S COM Mains Powered Version Power Supply S COM X, Y and Z can be connected to Room/Outdoor/Limit Sensor or contact The TP7001 and TP7001M can incorporate three inputs/sensor types by using input b, C and d.
  • Page 7: Tamperproof Operation

    4.1 Service Interval Timer Instructions on how to access this feature are available from our customer support desk. Please note these are only issued to boni-fi de heating installers. Danfoss Heating...
  • Page 8: Entering Installer Advanced Programming

    4.2 Entering Installer Advanced Programming To access the Installer Advanced Programming Mode follow the steps below: a) Press and hold and PROG for 3 seconds to enter User Advanced Programming, the display will change to look like the image opposite. Λ...
  • Page 9 Press + until Option 34 is displayed, use V or Λ to select required setting. 0 = On/Off 3 = 3 cycles/hour 6 = 6 cycles/hour (Factory setting) 9 = 9 cycles/hour 12 = 12 cycles/hour Danfoss Heating...
  • Page 10 Option 35 - Set Integration Time (Option 34 set to 3, 6, 9 or 12) This adjusts the integration time of the PI algorithm to increase control accuracy. It is only active if Option 34 has been set to Chrono 3, 6, 9 or 12. It should only be adjusted after seeking advice from the manufacturer.
  • Page 11 STAT in option 40. 7 = 7 Day (Factory Setting) 5-2 = 5+2 Day (or A-B if A days is set in option 1) 24 = 24 Hour Danfoss Heating...
  • Page 12 Option 70 - Keyboard Disable Rules This establishes the degree of functionality of the keyboard available to the user. It is only active if DIL switch 1 is set to ‘disabled’ . Press + until Option 70 is displayed, use V or Λ to select required setting. 0 = Normal Lock - Programming Functions Locked (Factory Setting) 1 = Full Lock - All keys are disabled...
  • Page 13 This allows the thermostat calibration to be biased by up to ±1.5°C. Press + until Option 81 is displayed, use V or Λ to select required setting. Any value between -1.5ºC and 1.5ºC in 0.5ºC steps Factory setting is 0.0ºC Danfoss Heating...
  • Page 14 Option 90 - Defi ne Remote Sensor Type (Remote sensor 1 - Backplate connection b) This allows type of remote sensor input type to be defi ned. Press + until Option 90 is displayed, use V or Λ to select required setting. 0 = No Sensor (Factory setting) 1 = Remote room or Duct sensor, internal sensor disabled...
  • Page 15 The temperature set for the limit point sensor will be determined by the type of fl oor. The recommended limits are: Tiles on chipboard and wooden fl oors 27°C Carpet or vinyl on chipboard 35°C Tiles on concrete fl oor 40°C Concrete, screed, etc 45°C Danfoss Heating...
  • Page 16 Option 94 - Confi gure Digital Input Switch Type (One of options 90-92 set to 3) This allows the switch type of the digital input to be confi gured. Press + until Option 94 is displayed, use V or Λ to select required setting. This option is only possible if one remote sensor option is set to Digital Input (Setting 3) 0 = Contacts Normally Closed, open circuit contact...
  • Page 17: Reset Procedure

    3. Hold down the PROG button 4. Press and release the RESET button This resets event times and all User and Installer Advanced Programming settings and returns them to factory settings, however, time, date and service due date are not reset. Danfoss Heating...
  • Page 18 TP7001...
  • Page 19 Danfoss Heating...
  • Page 20 Danfoss Ltd. Ampthill Road Bedford MK42 9ER Tel: 01234 364621 Fax: 01234 219705 Email: ukheating@danfoss.com Website: www.heating.danfoss.co.uk Part No. 37034v02 11/12...