Outdoor Installation - Takagi AT-KJr3U-IN Installation Manual And Owner's Manual

On-demand water heaters series 200
Table of Contents

Advertisement

Horizontal Installation with the 9008900005 vent kit
For the Direct vent kit of 9008900005, set the following DIP switch settings.
110U Indoor (AT-KJr3U-IN)
310U Indoor (AT-K5U-IN)
ON 1 2 3 4 5 6 7 8 9 10
OFF
Single Pipe
with Room-Air Intake
Backflow
preventer*
Vertical
condensation
drain**
*Backflow preventer (Recommended for freezing weather conditions: 36 °F (2 °C) and below.)
**Vertical condensation drain must be installed in accordance with local codes. It is
ing system when there is more than 5 ft. (1.5 m) of equivalent vent length, not including the sidewall termination. 90° elbow is
equivalent to 5 ft. (1.5 m) of vent length.
110U Outdoor (AT-KJr3U-OS)
310U Outdoor (AT-K5U-OS)
ON 1 2 3 4 5 6 7 8 9 10
OFF
510U Indoor (AT-D3U-IN)
(Upper bank of DIP switches)
No. 6 : O N
ON 1 2 3 4 5 6 7 8
No. 7 : O N
OFF
No. 8 : OFF
Two-Pipe, Direct-vent
sidewall Installation
Backflow
preventer*
Vertical
condensation
drain**
Outdoor Installation DIP switch settings

Outdoor installation

510U Outdoor (AT-D3U-OS)
(Upper bank of DIP switches)
No. 6 : OFF
ON 1 2 3 4 5 6 7 8
No. 7 : O N
OFF
No. 8 : OFF
22
No. 3 : ON
No. 4 : ON
(0 to 16.8 m)
No. 5 : OFF
3 - 7"
9008899005
(Termination)
2 - 5"
9008900005 (Termination + Thimble)
Covering wall thicknesses
Termination
Wall Thimble
Termination + Thimble
required to be installed in the vent-
No. 3 : OFF
No. 4 : O N
No. 5 : OFF
Page
Installation Manual
Installation
Vent length
0 to 55 ft.
3 - 6"
9008898005
(Wall Thimble)
Part#
9008899005
9008898005
9008900005