Service and Repair Manual
Platform Controls
8
Raise the primary boom to the fully elevated
position.
Note: Manually reduce the boom speed as it
reaches the fully elevated position.
9
Momentarily activate the drive enable toggle
switch to the right 1 time to set the elevated
position.
Result: The alarm will sound indicating that the
angle sensor has been calibrated.
10 Release the joystick and the foot switch and
wait for 10 seconds.
Result: The alarm will sound indicating that the
settings have been saved and is leaving
calibration mode.
11 Cycle the red Emergency Stop button off, then
back on. Start the machine and return to the
stowed position.