Genie S-80 Service And Repair Manual page 117

Hide thumbs Also See for S-80:
Table of Contents

Advertisement

October 2016
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN FMI
KWP
Description
105
0
996
High charged air cooler
temperature; warning threshold
exceeded
105
0
997
High charged air cooler
temperature; shut off threshold
exceeded
105
3
994
Sensor error charged air
temperature; signal range check
high
105
4
995
Sensor error charged air
temperature; signal range check
low
108
3
412
Sensor error ambient air press.;
signal range check high
108
4
413
Sensor error ambient air press.;
signal range check low
110
0
98
High coolant temperature;
warning threshold exceeded
110
0
99
High coolant temperature; shut
off threshold exceeded
110
3
96
Sensor error coolant temp.;
signal range check high
110
4
97
Sensor error coolant temp.;
signal range check low
111
1
101
Coolant level too low
132
11
1
Air flow sensor load correction
factor exceeding the maximum
drift limit; plausibility error
132
11
2
Air flow sensor load correction
factor exceeding drift limit;
plausibility error
132
11
3
Air flow sensor low idle correction
factor exceeding the maximum
drift limit
132
11
4
Air flow sensor load correction
factor exceeding the maximum
drift limit
157
3
877
Sesnor error rail pressure; signal
range check high
157
4
878
Sensor error rail pressure; signal
range check low
Part No. 1269074
Deutz D 2.9 L4 Engine Fault Codes
SPN FMI
168
0
168
1
168
2
168
2
168
3
168
4
171
3
171
4
172
0
172
1
172
2
172
2
172
3
172
4
174
0
174
0
175
0
175
0
175
0
175
1
S-80 • S-85 • S-80X
Service and Repair Manual
KWP
Description
1180
Physical range check high for
battery voltage
1181
Physical range check low for
battery voltage
47
High battery voltage; warning
threshold exceeded
48
Low battery voltage; warning
threshold exceeded
45
Sensor error battery voltage;
signal range check high
46
Sensor error battery voltage;
signal range check low
417
Sensor error environment
temperature; signal range check
high
418
Sensor error environment
temperature; signal range check
low
1182
Physical range check high for
intake air temperature
1183
Physical range check low for
intake air temperature
9
Sensor ambient air temperature;
plausibility error
983
Intake air sensor; plausibility
error
981
Sensor error intake air; signal
range check high
982
Sensor error intake air sensor;
signal range check low
481
High low fuel temperature;
warning threshold exceeded
482
High Low fuel temperature; shut
off threshold exceeded
740
Physical range check high for oil
temperature
745
High oil temperature; warning
threshold exceeded
746
High oil temperature; shut off
threshold exceeded
741
Physical range check low for oil
temperature
101

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-85S-80x

Table of Contents