Fan - Vaillant ECOmax VUW 236 EH Instructions For Installation And Servicing

Table of Contents

Advertisement

7.1.5 Removal of combustion
chamber cover (fig. 59).
Remove front casing as in Section
7.1.3,
Slacken the 2 case retaining screws
(2).
Undo the 5 captive inner casing
screws (3).
Remove screw (4).
Lift combustion chamber cover (5)
off boiler.
Check condition of case seal, and
if necessary replace before refitting.
Reassemble in reverse order, en-
suring that the cover case is correct-
ly fitted and a good seal obtained.
7.1.6 Lower front control panel
(fig. 60)
Remove front casing as in Section
7.1.3,
Undo screw (1) and lower control
box forward from top.
7.2 Replacement of fan
Isolate the boiler from the electrical
supply.
Remove front casing as in Section
7.1.3, and remove combustion
chamber cover as in Section 7.1.5.
Disconnect the 2 plug-in fan
connections (1, fig. 7.3).
Remove the 2 fan securing bolts
(7, fig. 61).
Remove fan inlet restrictor
(3, fig. 61) and fit to new fan.
Remove fan.
Replace fan mounting gasket
(1, fig. 62) with new gasket sup-
plied with fan.
Reassemble in reverse order,
making sure that the 2 fan securing
bolts are fully tightened.
Re-fit combustion chamber and front
casing.
Carry out electrical checks
(see Section 5.1).