7.6 Replacement of condensate
sump
Isolate the boiler from the electrical
supply.
Remove front casing as in Section
7.1.3 and remove combustion
chamber cover as in Section 7.1.5
Pull the condensate sump retaining
clip (1, fig. 67) forward to release
sump.
Remove two securing clips (6, fig.
68) by pulling the top of the
securing clip up and forward.
Rotate sump draw handle (2, fig.
67) until it is pointing forward, then
slide it down into the condensate
trap (3, fig. 67) clear of the sump.
Remove sump by pulling it down at
the front and forward.
Check gaskets (1, fig. 69) before
replacing.
Replace in reverse order.
fig. 68 (Natural Gas)
fig. 67
fig. 68a (Propane)
fig. 69