Disconnect three cable plugs
(1, fig. 100).
Disconnect two earth wires (2,
fig. 100) from earth terminal strip.
Remove screw (3, fig. 100).
Remove wiring terminal box cover
by undoing two screws
(1, fig. 101).
Disconnect wires from relay panel
at wiring connector strip.
Remove screw (4, fig. 102) and
remove suppressor (5, fig. 102).
Lift cable grommets (4, fig. 100)
out of grommet channel.
Squeeze together retaining clip
points (5, fig. 100) and lift panel
up at the front and forward to
remove.
Replace in reverse order.
NOTE: When refitting relay board
ensure that the on/off control knob
spindle is correctly aligned with the
hole in on/off switch of the panel,
and that rib of on/off switch (a,
fig. 103) correctly engages into
groove of knob spindle.
Carry out electrical checks
(see Section 5.1)