Undo screws (7, fig. 80) and
remove transformer by pulling it
down and to the right.
Reassemble in reverse order.
Carry out electrical checks
(see Section 5.1).
7.13 Replacement of ignition
transformer (fig. 81)
Isolate the boiler from the electricity
supply.
Remove front casing as in Section
7.1.3.
Lower front panel as in Section
7.1.6.
Remove screw (1) and slide spark
generator forward to release from
boiler chassis.
Disconnect leads by undoing two
cable grips (2) and pull out.
Pull off mains connection cover
(3) and disconnect electrical
connections.
Reassemble in reverse order.
- Carry out electrical checks
(see Section 5.1).
7.14 Replacement of pump
- Turn boiler off as in Section 7.1.1.
- Release pressure and drain boiler
as in Section 7.1.2.
- Remove front casing as in Section
7.1.3.
- Lower front control panel as in
Section 7.1.6.