H Position Of The Opening In The Air/Flue Pipe; Positioning Of The Opening Of A Fan-Supported Flue Gas Pipe - Vaillant ecoTEC plus VU 446/5-5 (H-GB) Installation And Maintenance Instructions Manual

Hide thumbs Also See for ecoTEC plus VU 446/5-5 (H-GB):
Table of Contents

Advertisement

Appendix
H
Position of the opening in the air/flue pipe
Applicability: Great Britain
OR Ireland
J
H.1

Positioning of the opening of a fan-supported flue gas pipe

Applicability: Great Britain
OR Ireland
Installation site
A
Directly below an opening, air bricks, opening windows, etc., that can be opened.
B
Above an opening, air bricks, opening windows, etc., that can be opened.
C
Horizontally to an opening, air bricks, opening windows, etc., that can be opened.
Below temperature-sensitive building components, e.g. plastic gutters, down pipes or wastewater
D
pipes
E
Below eaves
F
Below balconies or car port roofs
G
From vertical wastewater pipes or down pipes
H
From external or internal corners
I
Above floors, roofs or balconies
J
From a surface facing a terminal
K
From a terminal facing a terminal
L
From an opening in the car port (e.g. door, window) which leads into the dwelling
M
Vertical from a terminal on the same wall
N
Horizontal from a terminal on the same wall
O
From the wall on which the terminal has been installed
P
From a vertical structure on the roof
Q
Above the roof area
R
Horizontal from adjacent windows on pitched or flat roofs
S
Above adjacent windows on pitched or flat roofs
T
Below adjacent windows on pitched or flat roofs
60
P
D, E
O
B
C
A
G
I I
Installation and maintenance instructions ecoTEC plus 0020261389_02
N
N
Minimum dimen-
sions
300 mm
300 mm
300 mm
75 mm
200 mm
200 mm
150 mm
200 mm
300 mm
600 mm
1,200 mm
1,200 mm
1,500 mm
300 mm
0 mm
300 mm
300 mm
600 mm
600 mm
2,000 mm

Hide quick links: