Instruction Leaflet
ranges outlined in "UL Testing and Specification
COMPLIANCE TESTING:
Certifications:
CUL/UL Recognized, File # E154862
CAN/CSA C22.2 No. 14-M91 Industrial Control Equipment
th
UL 1053 (6
Edition 1999)
ANSI C37.90 (1989)
EN 61010-1 (1993)
EN 55011 (1991)
Emission Tests:
EN 55011 (1991) - Group 1 Class A
FCC 47 CFR Chapter 1 - Part 15 Subpart b Class A
Immunity Tests:
ANSI C37.90.1 (2002) – Surge Withstand Capability 2.5KV
OSWC, 4KV FTSWC
ANSI C37.90.2 (2004) – RF Radiated Withstand Capability
to 35V/M – AM 1KHz, 80% Modulation
EN61000-4-2 (1995) – ESD Immunity to 8KV
IEC 255-22-2 (1989) - ESD Immunity to 8KV
EN61000-4-3 (1995) – RF radiated Immunity to 10V/M
IEC 255-22-3 (1989) - RF radiated Immunity to 10V/M
EN61000-4-4 (1995) - Electrical Fast Transient Immunity to
10V/M
IEC 255-22-4 (1989) - Electrical Fast Transient Immunity to
10V/M
EN61000-4-5 (1995) – Surge Immunity 2/1KV C/DM
EN61000-4-6 (1996) – RF conducted Immunity to 10Vo
EN61000-4-11 (1994) – Voltage Dip. Short Int., Variations
Immunity
CURRENT INPUTS:
Ct:
Ct Burden:
Saturation:
Momentary:
Ct Thermal Rating:
TIMING ACCURACY:
±50ms
ADDITIONAL TESTS:
Dielectric Strength:
Current Inputs: 3,000Vac for 1 minute Phase to Phase
Seismic Test:
Meets requirements for UBC and California Building Code
Zone 4
ZPA = 3.5
Effective: Date 03/2006
2-3 MD-3000 SPECIFICATIONS AND TEST SUMMARY
5A Secondary
<0.1 VA @ Rated Current (5A)
5A (Secondary or Ct (Primary)
100 x I
n
10A continuous
500A for 1 Second
For more information visit:
MD-3000
IB02602001E
Summary."
OUTPUT TRIP CONTACTS:
(Differential Trip)
Momentary:
Continuous:
Meets ANSI C37.90, paragraph 6.7
CONTROL POWER:
Input Voltage:
MD-3000:
Power Consumption:
MD-3000
CT (PRIMARY) SETTING AVAILABLE:
Phase
5/10/25/50/75/100/150/200/250/300/400/500/
600/630/800/1000/1200/1250/1500/1600/
2000/2400/2500/3000/3200/4000/5000
AUXILIARY RELAY:
Trip Alarm
Make/Break:
<0.004 ohm
Continuous:
CURRENT MONITORING:
28 x I
True rms Sensing:
n
Display Accuracy:
for 1 Second
ENVIRONMENT:
Environment:
Indoor Use Only, Pollution Degree II, Altitude 2,500m,
Installation Category II
Mounting Location:
Device should be positioned near the main disconnect
Operating temperature:
-30 to +55 Degrees Celsius
Operating Humidity:
0 to 95% Relative Humidity [Non-Condensing]
Storage Temperature:
www.EatonElectrical.com
Initial Release
Make 30A ac/dc for 0.25 sec
Break 0.25A @ 250Vdc
Break 5A @ 120/240Vac
Nominal
Oper. Range
48 to 250Vdc
28 to 280Vdc
120 to 240Vac
66 to 264Vac
(50/60Hz)
(50/60Hz)
48
125
250
Vdc
Vdc
Vdc
10VA
10VA
10VA
5A @ 120/240Vac & 30Vdc
5A @ 120/240Vac
5A @ 30Vdc
+1% of Full Scale [I
] from 0.04 x I
n
+2% of Full Scale [I
] from 1 x I
n
-40 to +70 Degrees Celsius
5A @ 120/240Vac
5A @ 30Vdc
120
240
Vac
Vac
10VA
18VA
3-Phase
to 1 x I
n
n
to 2 x I
n
n