Lutron Electronics AM-4205A Operation Manual
Lutron Electronics AM-4205A Operation Manual

Lutron Electronics AM-4205A Operation Manual

+ type k/j temp. humidity / anemometer

Advertisement

Quick Links

+ Type K/J TEMP.
HUMIDITY /
ANEMOMETER
Model : AM-4205A
Your purchase of this HUMIDITY/ANEMOMETER marks a step
forward for you into the field of precision measurement.
Although this METER is a complex and delicate instrument, its
durable
structure
instructions carefully and always keep this manual within easy
reach.
OPERATION MANUAL
developed.
Please
read
the
following

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AM-4205A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lutron Electronics AM-4205A

  • Page 1 + Type K/J TEMP. HUMIDITY / ANEMOMETER Model : AM-4205A Your purchase of this HUMIDITY/ANEMOMETER marks a step forward for you into the field of precision measurement. Although this METER is a complex and delicate instrument, its durable structure developed.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. FEATURES..............1 2. SPECIFICATIONS............2 2-1 General Specifications..........2 2-2 Electrical Specifications ..........5 3. FRONT PANEL DESCRIPTION.......... 7 3-1 Display..............7 3-2 Power Button ( ESC Button )........7 3-3 Hold Button ( Function Button )......... 7 3-4 REC Button ( Enter Button )........
  • Page 3: Features

    1. FEATURES * Anemometer, Humidity meter and type K/J Thermometer are combined into one meter, intelligent design. * Microprocessor circuit assures maximum possible accuracy, provides special functions and features. * Large LCD with two display, easy readout. * Low-friction ball vane wheels is accurate in both high & low velocities for anemometer.
  • Page 4: Specifications

    2. SPECIFICATIONS 2-1 General Specifications Circuit Custom one-chip of microprocessor LSI circuit. Display * LCD size : 60 mm x 33 mm * Dual function meter's display. Anemometer : Measurement m/s ( meters per second ) km/h ( kilometers per hour ) ft/min ( feet/per minute ) knots ( nautical miles per hour ) mile/h ( miles per hour )
  • Page 5 Input Socket : Type K/J Thermometer Standard 2 pin thermocouple socket. Linear Compensation : structure Linear Compensation for the full range. Temperature Compensation : Automatic cold junction compensation both type K/J thermometer Data hold To freeze the display reading on the LCD display.
  • Page 6 Main instrument: Dimension 180x72x32 mm (7.1x2.8x1.3 inch). Anemometer probe : Round, 72 mm Dia. Humidity Probe: 197 mm ( 7.8 inch ) in length. Accessories Instruction manual....1 PC. Included Anemometer probe....1 PC. Humidity Probe......1 PC. Carrying case......1 PC. Optional * Type K thermocouple probe, Accessories...
  • Page 7: Electrical Specifications

    2-2 Electrical Specifications (23± 5 ℃ Type K/J Thermometer Sensor Reso- Range Accuracy Type lution 0.1 ℃ Type K -50.0 to 1300.0 ℃ ± ( 0.4 % + 0.8 ℃ -50.1 to -199.9 ℃ ± ( 0.4 % + 1 ℃...
  • Page 8 B. Temperature Measuring Range to 50 to 122 ℃ ℃ ℉ ℉ Resolution /0.1 ℃ ℉ Accuracy ± 0.8 /1.5 ℃ ℉ Humidity/Temp. meter A. Humidity Measuring Range 10 % to 95 % R.H. Resolution 0.1 % R.H. Accuracy 70% RH ±...
  • Page 9: Front Panel Description

    3. FRONT PANEL DESCRIPTION Fig. 1...
  • Page 10: Display

    Fig. 2 3-1 Display 3-2 Power Button ( ESC Button ) 3-3 Hold Button ( Function Button ) 3-4 REC Button ( Enter Button ) 3-5 Setting Button 3-6 RS-232 Output Terminal 3-7 Vane Probe Head 3-8 Vane Probe Handle 3-9 Vane Probe Plug 3-10 Humidity Probe Head 3-11 Humidity Probe Handle...
  • Page 11: Measuring Procedure

    4. MEASURING PROCEDURE 4-1 ANEMOMETER 1) Install the " Vane Probe Plug " ( 3-9, Fig. 1 ) into the " Anemometer Socket " ( 3-13, Fig. 2 ). 2) Power on the meter by pressing the " Power Button " ( 3-2 , Fig.
  • Page 12: Humidity Meter

    4-2 HUMIDITY METER 1) Install the " Humidity Probe Plug " ( 3-12, Fig. 1 ) into the " Humidity Socket " ( 3-13, Fig. 2 ). 2) Power on the meter by pressing the " Power Button " ( 3-2 , Fig. 1 ) once. 3) The display will show the humidity ( %RH ) and temperature value that sening from "...
  • Page 13: Both Anemometer/Thermometer

    4-4 Both Anemometer/Thermometer 1) Install the " Vane Probe Plug " ( 3-9, Fig. 1 ) into the " Anemometer Socket " ( 3-13, Fig. 2 ). Connect the plug of the Temp. probe ( optional, such as type K probe, TP-01, TP-02A, TP-03, TP-04 ) into the " Thermometer socket "...
  • Page 14: Data Hold

    4-6 Data Hold During the measurement, pushing the " Data Hold Button " ( 3-3, Fig. 1 ) will hold the measured value & the LCD will indicate " HOLD " symbol. * Push the "Data Hold Button" again to release the data hold function.
  • Page 15 5. ADVANCED SETTING PROCEDURES Before executing Advanced Setting Procedures, exit the " Hold function " and the Record " function first. * Press " Setting Button " continuously at least 5 seconds to enter the setting function. * After already set the desiring value ( function ), press the "...
  • Page 16: Change The Measuring Unit

    5-1 Change the measuring unit Change the measurement unit are available for Anemometer a. Use " Function button " ( 3-3, Fig. 1 ) to select the desiring measuring unit. Anemometer m/S, km/h, mph, knot, FPM b. After select the desiring unit, press the " Enter button "...
  • Page 17: Auto Power On/Off

    5-4 Auto power On/Off ( Lower display show " OFF " ) a. Use " Function button " ( 3-3, Fig. 1 ) to select " YES " or " no ". * YES : Auto power off. * no : Auto power disable. b.
  • Page 18: Rs232 Pc Serial Interface

    6. RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3.5 mm terminal ( 3-6, Fig. 1 ). The data output is a 16 digit stream which can be utilized for user's specific application. A RS232 lead with the following connection will be required to link the instrument with the PC serial port.
  • Page 19 Each digit indicates the following status : Start Word When send the upper display data = 1 When send the lower display data = 2 D12 & D11 Annunciator for Display = 01 = 02 m/S = 08 ℃ ℉ km/h = 10 mph = 12 knot = 09...
  • Page 20: Battery Replacement

    7. BATTERY REPLACEMENT 1) When the left corner of LCD display show " ", it is necessary to replace the battery. However, in-spec. measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate. 2) Open the "...
  • Page 21 (Type K) TP-01 * Max. short-tern operating Temperature: 300 (572 ℃ ℉ * It is an ultra fast response naked-bead thermocouple suitable for many general purpose application. Thermocouple * Measure Range : Probe -50 to 900 , -50 to 1650 ℃...

Table of Contents