Summary of Contents for Lutron Electronics DM-9983G
Page 1
Green power, hybrid power SMART MULTIMETER Model : DM-9983G Your purchase this SMART MULTIMETER marks a step forward for into field precision measurement. A l t h o u g h t h i s MULTIMETER is a complex and delicate instrument, its...
Caution Symbol Caution : * Risk of electric shock ! Caution : * Do not apply the overload voltage, current to the input terminal ! * Remove test leads before open the battery cover ! * Cleaning - Only use the dry cloth to clean the plastic case ! Environment Conditions * Installation Categories III 600V.
Page 3
TABLE OF CONTENTS 1. FEATURES..............1 2. SPECIFICATIONS............2 3. FRONT PANEL DESCRIPTION........6 3-1 Display..............6 3-2 Power ON button..........6 3-3 Hold button............6 3-4 Select button............6 3-5 Hz button............6 3-6 Range button ............6 3-7 Function switch............6 3-8 V/Ω terminal ............6 3-9 COM terminal ............6 3-10 mA terminal............6 3-11 10 A terminal.............6...
Page 4
1. FEATURES * Green power, battery is no need, power supply from the handy generator, operate the generator 10 to 20 seconds will offer 10 minutes energy typically. * Hybrid power, meter also can supply by the battery. * Meet CAT III-600 V. * 6000 counts A/D, high resolution.
2. SPECIFICATIONS 2-1 General Specifications Green power * Green power, battery is no need, power supply from the handy Hybrid power generator, operate 10 to 20 seconds the generator will offer 10 minutes energy typically. * Hybrid power, meter also can supply by the battery power.
Page 6
Operating Less than 80% RH. humidity Power Green power : Supply Power from the handy generator, battery is no need. Battery power : DC 3V battery ( CR-2032 ) x 2 PCs. Power consumption DC 3 mA. Weight 340 g/0.75 LB. Dimension 152 x 78 x 45 mm ( 6.0 x 3.1 x 1.8 inch )
Page 7
DC/AC Current * auto range Range mA range 600 mA/60 mA 10 A range Resolution mA range 0.1 mA/0.01 mA 10 A range 0.01 A Accuracy mA range ± ( 1.2% + 2d ) 10 A range ± ( 1.5% + 2d ) Over load mA range 630 mA fuse...
Page 8
Diode Short/non conductance, good/defect test. Continuity If measuring resistance is less than 10 ohm, the beeper will sound .
3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Display 3-2 Power On button. 3-3 Hold button 3-4 Select button 3-5 Hz button 3-6 Range button 3-7 Function switch 3-8 V/Ω terminal 3-9 COM terminal 3-10 mA terminal 3-11 10 A terminal 3-12 Handle of power generator 3-13 Stand 3-14 Battery compartment/cover...
4. POWER TYPE SELECTION 4-1 Power supply from the generator ( Green power supply ) 1)Select the " Power type switch " ( 3-15, Fig. 1 ) to the " G position " ( Green power position ). There is a " Power generator's handle " ( 3-12, Fig. 1 ) on the top of the housing case.
4-2 Power supply from the battery Install the " DC3V battery ( CR-2032 ) x 2 PCs " into the " Battery compartment " ( 3-14, Fig. 1) Slide the " Power type switch " to the " B " position ( battery position ), the meter will offer the power source from the battery.
Page 12
5-3 Symbols & units of display Symbols Descriptions Units SMART Appears when selecting " Smart " mode. The meter default mode is " Smart " AUTO Appears when selecting " Automatic range " mode. MANU Appears when selecting " Manual range " mode. Appears when selecting DC mode.
5-4 Voltage ( ACV/DCV ) measurement 1)Connect BLACK test lead into " COM " terminal ( 3-9, Fig. 1 ). 2)Connect RED test lead into " V " terminal ( 3-8, Fig. 1 ). 3)Select the " Function switch " ( 3-7, Fig. 1 ) to the "...
5)When the resistance value is less than 10 ohm, the beeper sound will be generated, the Display will show " " indicator. Diode measurement 1)Connect BLACK test lead into " COM " terminal ( 3-9, Fig. 1 ). 2)Connect RED test lead into " Ω " terminal ( 3-8, Fig. 1 ). 3)Select the "...
Page 15
b. When connected as shown in Fig. 3, a reverse check on the diode is made. If the diode under test is good, " OL " will be displayed. If the diode under test is defective, " .000 " or other numbers will be displayed.
Page 16
5-8 Current mA ( AC/DC ) measurement 1)Connect BLACK test lead into " COM " terminal ( 3-9, Fig. 1 ). 2)Connect RED test lead into " mA " terminal ( 3-10, Fig. 1 ). Open the circuit in which current is to be measured.
3)Select the " Function switch " ( 3-7, Fig. 1 ) to the " 10 A " position. 4)Power On the meter by pressing the " Power On button " ( 3-2, Fig. 1 ) once, the Display will show " SMART ". the meter is under "...
5-12 Hz measurement During the measurement : Voltage ( ACV/DCV ) measurement ( Chapter 5-4 ) Current mA ( AC/DC ) measurement ( Chapter 5-8 ) current 10A ( AC/DC ) measurement ( Chapter 5-9 ) if press the " Hz button " ( 3-5, Fig. 1 ) once, the Display will show "...
Page 19
6-2 Replacement of Fuse When make the replacement, Caution : should change the right spec. fuse . a. Fuse A - Rating : 630 mA To be protected the circuit from overload current mA range ( 60 mA, 600 mA ). b.Fuse B - Rating : 10 A To be protected the circuit from overload current for...
Page 20
6-3 Replacement of batteries 1)When use the battery power, if the Display show Low battery indicator " " , it need to change the batteries. 2)open the " Battery Cover " ( 3-14, Fig. 1 ) away from the instrument and remove the battery. 3)Replace with batteries ( DC 3V, CR2032 X 2 PCs ) and reinstate the cover.