13.Pull out the catch before inserting the piston. Hold
the catch in this position until the piston is fully
inserted and its tip no longer projects from the tool.
14.Press the base plate and the fastener transport sys-
tem against the threaded section on the tool and
rotate it on in a clockwise direction until it is screwed
on as far as it will go.
15.Turn the base plate with the fastener transport sys-
tem back to its original position over the magazine.
16.Push the magazine back until it engages with the fas-
tener transport system.
8.3 Checking the tool after care and maintenance
After carrying out care and maintenance and before load-
ing the cartridges, check that all safety devices have been
fitted and that they function faultlessly.
-NOTE-
Use of lubricants other than Hilti lubricant spray may
cause damage to rubber parts of the tool, especially the
piston stopper.