Electrical Safety and Installation Requirements STANDARDS: This product meets the following standards U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Page 4
Electrical Safety and Installation Requirements INSTALLATION LIGHTNING DANGER DANGER: DO NOT WORK on equipment or CABLES during periods of LIGHTNING ACTIVITY. CAUTION: POWER CORD IS USED AS A DISCONNECTION DEVICE. TO DE-ENERGISE EQUIPMENT disconnect the power cord. ELECTRICAL—AUTO VOLTAGE ADJUSTMENT This product will automatically adjust to any voltage between the ranges shown on the label.
Page 5
AT-MS201 and AT-MS202 Installation Guide VORSICHT: DAS NETZKABEL DIENT ZUM TRENNEN DER STROMVERSORGUNG. ZUR TRENNUNG VOM NETZ, KABEL AUS DER STECKDOSE ZIEHEN. AUTOMATISCHE SPANNUNGSEINSTELLUNG Dieses Gerät stellt sich automatisch auf die auf dem Etikett aufgeführten Spannungswerte ein. GERÄTE DER KLASSE 1 DIESE GERÄTE MÜSSEN GEERDET SEIN.
Page 6
Electrical Safety and Installation Requirements INSTALLATION FARE UNDER UVEJR FARE: UNDLAD at arbejde på udstyr eller KABLER i perioder med LYNAKTIVITET. ADVARSEL: DEN STRØMFØRENDE LEDNING BRUGES TIL AT AFBRYDE STRØMMEN. SKAL STRØMMEN TIL APPARATET AFBRYDES, tages ledningen ud af stikket. ELEKTRISK—AUTOMATISK SPÆNDINGSREGULERING Dette apparat vil automatisk tilpasse sig enhver spænding indenfor de værdier, der er angivet på...
Page 7
AT-MS201 and AT-MS202 Installation Guide INSTALLATIE GEVAAR VOOR BLIKSEMINSLAG GEVAAR: NIET aan toestellen of KABELS WERKEN bij BLIKSEM.\ WAARSCHUWING: HET TOESTEL WORDT UITGESCHAKELD DOOR DE STROOMKABEL TE ONTKOPPELEN.OM HET TOESTEL STROOMLOOS TE MAKEN: de stroomkabel ontkoppelen. ELEKTRISCH: AUTOMATISCHE AANPASSING VAN DE SPANNING Dit toestel past zich automatisch aan elke spanning aan, tussen de op het label vermelde waarden.
Page 8
Electrical Safety and Installation Requirements INSTALLATION DANGER DE FOUDRE DANGER : NE PAS MANIER le matériel ou les CÂBLES lors d’activité orageuse. ATTENTION : LE CORDON D’ALIMENTATION SERT DE MISE HORS CIRCUIT. POUR COUPER L’ALIMENTATION DU MATÉRIEL, débrancher le cordon. RÉGLAGE DE TENSION AUTOMATIQUE ÉLECTRIQUE Ce matériel peut s’ajuster automatiquement sur n’importe quelle tension comprise dans la plage indiquée sur l’étiquette.
Page 9
AT-MS201 and AT-MS202 Installation Guide ASENNUS SALAMANISKUVAARA HENGENVAARA: ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA SALAMOINNIN AIKANA. HUOMAUTUS: VIRTAJOHTOA KÄYTETÄÄN VIRRANKATKAISULAITTEENA. VIRTA KATKAISTAAN irrottamalla virtajohto. SÄHKÖ—AUTOMAATTINEN JÄNNITTEENSÄÄTÖ Tämä tuote säätää automaattisesti mihin tahansa jännitteeseen ohjetarrassa annettujen arvojen välillä. SÄHKÖ—TYYPPILUOKAN 1 LAITTEET TÄMÄ...
Page 10
Electrical Safety and Installation Requirements INSTALLAZIONE PERICOLO DI FULMINI PERICOLO: NON LAVORARE sul dispositivo o sui CAVI durante PRECIPITAZIONI TEMPORALESCHE. ATTENZIONE: IL CAVO DI ALIMENTAZIONE È USATO COME DISPOSITIVO DI DISATTIVAZIONE. PER TOGLIERE LA CORRENTE AL DISPOSITIVO staccare il cavo di alimentazione.
Page 11
AT-MS201 and AT-MS202 Installation Guide Dette er et “KLASSE 1 LED PRODUKT” INSTALLASJON FARE FOR LYNNEDSLAG FARE: ARBEID IKKE på utstyr eller KABLER i TORDENVÆR. FORSIKTIG: STRØMLEDNINGEN BRUKES TIL Å FRAKOBLE UTSTYRET. FOR Å DEAKTIVISERE UTSTYRET, må strømforsyningen kobles fra.
Page 12
Electrical Safety and Installation Requirements INSTALAÇÃO PERIGO DE CHOQUE CAUSADO POR RAIO PERIGO: NÃO TRABALHE no equipamento ou nos CABOS durante períodos suscetíveis a QUEDAS DE RAIO. CUIDADO: O CABO DE ALIMENTAÇÃO É UTILIZADO COMO UM DISPOSITIVO DE DESCONEXÃO. PARA DESELETRIFICAR O EQUIPAMENTO, desconecte o cabo de ALIMENTAÇÃO.
Page 13
AT-MS201 and AT-MS202 Installation Guide Este es un “PRODUCTO DE DIODO LUMINISCENTE (LED) CLASE 1” INSTALACION PELIGRO DE RAYOS PELIGRO: NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los equipos o en LOS CABLES durante TORMENTAS ELECTRICAS. ATENCION: EL CABLE DE ALIMENTACION SE USA COMO UN DISPOSITIVO DE DESCONEXION.
Page 14
Electrical Safety and Installation Requirements STANDARDER: Denna produkt uppfyller följande standarder. Radiostörning EN55022 Klass B Immunitet EN50082-1 Elsäkerhet EN60950, UL1950, CSA 950 Laser EN60825 SÄKERHET TILLKÄNNAGIVANDEN BETRÄFFANDE ELEKTRICITETSRISK: RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt, ta ej av locket. Det finns inga delar inuti som behöver underhållas.
Table of Contents Electrical Safety and Installation Requirements ........iii Chapter 1 Product Description ..................1 Overview ......................1 Features ......................2 Switch Performance ....................4 Physical Description....................4 ST/SC Fiber Connectors................5 UTP RJ45 Connector ...................5 MDI/MDI-X Crossover Switch ..............5 LEDs ......................6 Configuration Switch ...................6 Full Duplex Configuration................7 Reset Button ....................7 AC Power Connector ..................7...
Page 16
Electrical and Mechanical Specifications ............15 Pinout Assignments..................16 Cable Specifications and Requirements........... 17 Appendix B Technical Support Fax Order ..............19 Appendix C AT-MS201/202 Micro Switch Installation Guide Feedback ....21 Appendix D Where To Find Us ..................23...
Chapter 1 Product Description Overview The AT-MS201 (ST) and AT-MS202 (SC) Fast Ethernet Micro Switch is a self- learning, unmanaged dual- port 10Base-T/100Base-TX and 100Base-FX Ethernet switch which is capable of Forwarding and filtering data packet at full wire speed (10/100 Mbps)
For definitions concerning Allied Telesyn’s technical terms, refer to the Glossary at Allied Telesyn’s website at www.alliedtelesyn.com. Features AT-MS201 (ST) /202 (SC) Micro Switch has the following major features: One 10/100Base-TX port for Ethernet/Fast Ethernet connectivity One 100Base-FX for Fast Ethernet connectivity...
Page 19
AT-MS201 and AT-MS202 Installation Guide Multimode fiber (MMF) 50/100 or 62.5/125 micron cable Up to 100 meters maximum cable distance for TX port and up to 2Km for FX port end station connection Full compatibility with other Allied Telesyn 10/100 Mbps products Figure 2 shows a typical configuration using the AT-MS202 (SC) Micro Switch...
Product Description Switch Performance The AT-MS201/202 Micro Switch performs at: Up to 148,800 pps for 100Mbps and 14,880 pps for 10 Mbps for full wire speed forwarding and filtering 200 Mbps maximum throughput in 100 Mbps, full duplex mode Twisted pair port provides full duplex at 10 Mbps; fiber port provides...
AT-MS201 and AT-MS202 Installation Guide ST/SC Fiber Connectors The AT-MS201 features the ST fiber connector; the AT-MS202 features the SC fiber connector. These fiber connectors provide an uplink to other fiber hubs. Some of the major reasons for using these fiber connectors include:...
Product Description LEDs Table 1 shows lists and defines the port and system LEDs. Table 1: Port and System LEDs Color Description Green ON indicates that the switch is transmitting signals Green ON indicates that the switch is receiving signals Yellow ON indicates data collisions (half duplex mode) LINK...
The power off/on cycle also is the equivalent of the RESET button. AC Power Connector AT-MS201/202 Micro Switch has an internal universal power supply rated at 100-240 VAC, 50/60 Hz. A 100-120 VAC power cord (Americas only) supplies the power for all the internal electronics and LEDs.
Product Description Functional Description The AT-MS201(ST)/202(SC) Micro Switch functions as an unmanaged dual- port switch or switch without Spanning Tree and Address Aging support. Frame Processing The switch supports store and forward switching at Fast Ethernet full-wire speed either in 10 or 100 Mbps, half or full duplex mode. Packets entering each port are stored in buffers.
Installation of this product should only be performed by TRAINED SERVICE PERSONNEL. Verifying Package Contents Make sure the package includes all of the required parts, including: AT-MS201/202 Fast Ethernet Micro Switch Power cord (Americas version only) This installation guide Note If any of the above items are missing or damaged, notify your Allied Telesyn sales representative.
Installation and Troubleshooting Note Electrostatic Discharge Precautions. Static electricity can damage electronic components of a computer or optional equipment. To prevent electrostatic damage, observe the following precautions: Avoid hand contact by transporting and storing products in static- safe containers. Keep electro-sensitive parts in their containers until they arrive at a static-free work place.
Page 27
6. Verify that the LEDs indicate the correct configuration. You are now ready to operate your AT-MS201/202 Micro Switch in a network configuration. The switch supports a maximum of 8,192 MAC addresses in the forwarding table.
If the POWER LED is not on, check both ends of the AC power cord. Make sure the power cord is plugged into a functioning wall outlet and that it is properly inserted into the AT-MS201/202 Micro Switch power connector.
AT-MS201 and AT-MS202 Installation Guide Is the LINK LED lit? The LINK LEDs light when a proper connection between the corresponding 10Base-T/100Base-TX or 100Base-FX port and the equipment connected to it is established. If this LED is not lit, check for the problems listed as follows and make corrections as necessary.
Appendix A AT-MS201/202 Micro Switch Specifications Physical Specifications Dimensions: 10.5"L x 7.0"W x 1.75"H Operating temperatures: 0° to 50° C Storage temperatures: -20° to 80° C Relative humidity: 5% to 80% (non-condensing) Operating altitude: Up to 10,000 ft. Electrical and Mechanical Specifications Standard: CE Compliant IEEE 802.3, IEEE 802.3u...
AT-MS201/202 Micro Switch Specifications Pinout Assignments Figure 3 shows the switch’s 10Base-T/100Base-TX RJ45 connector with its pin assignments. Pin 1 Pin 8 Figure 3: RJ45 Pin Assignments Table 3: lists the 10Base-T/100Base-TX connector pins and their positions for the MDI-X and MDI switch.
AT-MS201 and AT-MS202 Installation Guide Cable Specifications and Requirements The AT-201/202 (ST/SC) Micro switch uses three types of cabling: UTP cable (RJ45 connector) for both 10Base-T and 100Base-TX STP cable (RJ45 connector) for both 10Base-T/100Base-TX Fiber optics cable (ST/SC connector) for 100Base-FX Table 4 provides an overview of IEEE 802.3 and 802.3u cabling specifications...
Appendix B Technical Support Fax Order Name__________________________________________________________________ Company _______________________________________________________________ Address ________________________________________________________________ City ________________________ State/Province _______________________________ Zip/Postal Code ___________________ Country _______________________________ Phone _______________________________ Fax _______________________________ Incident Summary Model number of Allied Telesyn product I am using _____________________________ Network software products I am using ________________________________________ ______________________________________________________________________ Brief summary of problem _________________________________________________ ______________________________________________________________________...
Appendix C AT-MS201/202 Micro Switch Installation Guide Feedback Please tell us what additional information you would like to see discussed in the guide. If there are topics you would like information on that were not covered in the guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn.
Appendix D Where To Find Us For Technical Support or Service Location Phone Americas 1 (800) 428-4835 1 (206) 481-3790 United States, Canada, Mexico, Central America, South America Asia (+65) 3815-613 (+65) 3833-830 Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India Australia (612) 416-0619 (612) 416-9764...
Page 40
Where To Find Us For Sales Information San Diego, CA Australia Tel: (619) 279-3899, Fax: (619) 279-3897 Lindfield, NSW Santa Ana, CA Tel: (612) 416-0619, Fax: (612) 416-9764 Tel: (714) 838-0434, Fax: (714) 838-9721 Canada Clearwater, FL Rexdale, Ontario Tel: (813) 726-0022, Fax: (813) 726-0234 Tel: (416) 675-6738, Fax: (416) 675-0057 Norcross, GA Richmond, British Columbia...