Description
Unknown FS!
The Professional Disc inserted in the library uses an unsupported file system.
Format or eject the disc.
ILL. Index!
An error occurred in the index file of the Professional Disc.
Format or eject the disc.
FORMAT NG!
Could not Auto Format.
Use another disc.
Read err
Cannot read the address from the Professional Disc.
DISC Error!
A disc requiring repairs was inserted.
Eject the disc, then repair the disc on another XDCAM device or format the disc.
XDROOT Error!
Clips in the USERDATA >XDROOT folder on the Professional Disc cannot be used.
BPAV Error!
Clips in the USERDATA >BPAV folder on the Professional Disc cannot be used.
Index File!
Unsupported index file. Data cannot be recorded on this Professional Disc.
Use another disc.
Verify ERR!
A Professional Disc error was detected.
Verify ERR! D2
A Professional Disc error was detected for the disc inserted in the optional Professional Disc Drive unit.
No FS!
Cannot detect the file system of the Professional Disc.
Eject the disc.
BCA Read Error!
Cannot read BCA area data on the Professional Disc or an error occurred.
DI Read Error!
Cannot read PIC area data on the Professional Disc or an error occurred.
ILL. Disc!
An unsupported Professional Disc was inserted.
Use another disc.
Disc Damage
Recording failed due to lack of free memory in the swap space of the Professional Disc.
Use another disc.
DRV ADJ err
Could not complete the startup adjustment or optical power calibration (OPC) of a Professional Disc Drive unit.
Over DUR!
The length of the clip on the Professional Disc exceeds the maximum limit. This disc cannot be used.
No Support!
Cannot record/play the Professional Disc as it contains unsupported clips.
REC INH!
Could not Auto Format as the write protection tab of the Professional Disc is set to SAVE.
Eject the disc.
DR-FAN Stop
Cannot detect operation of the fan in a Professional Disc Drive unit.
DRIVE2 detection
An optional Professional Disc Drive unit has been installed.
Check the device configuration in the [Setup Menu] of the web application.
PSU detect
A redundant power supply unit is installed.
Check the [Setup Menu] settings in the web application.
Unknown USB
An unsupported USB device was detected.
LCD Com Error
Cannot communicate with the LCD panel.
Door is Opening
The tray door is open.
WRONG
A Professional Disc was inserted in a slot reserved for another disc that is currently in use.
INSERTION
NO SYSINFO
The system configuration file cannot be found.
Reconfigure the serial number in the [Setup Menu] in the web application.
NO XDJ CONF
The library configuration file cannot be found.
Reconfigure the library in the [Setup Menu] in the web application.
NO NETWORK
The network configuration file cannot be found.
CFG
Reconfigure the network settings.
RFID Wr Err (xxx)
Could not write data to the xxx RFID tag due to a tag failure. Replace with a new tag.
xxx represents the bin or disc slot number.
RFID Rd Err (xxx)
Could not read data from the xxx RFID tag due to a tag failure. Replace with a new tag.
xxx represents the bin or disc slot number.
Exchg batt!
The lithium battery is scheduled for replacement. Replace the lithium battery.
LACK OF LOG
The remaining space in the LOG partition is low.
SPACE
Execute [Clear Log] on the [Maintenance Menu 1] screen of the web application.
48
Messages