MK-2000 ELECTRIC SAW
WATER PUMP SETUP FOR OPERATION
The Water Pump can be setup for operation in two ways, External Water Source or Re-circulation.
NOTE:
If using a dry blade for operation, DO NOT connect the water pump.
EXTERNAL WATER SOURCE
This is the preferred method of cooling.
1. Verify or remove the Drain Plug from the Water Pan.
2. Place the Water Pump in an external container.
3. Fill the external container until water completely covers the Water Pump suction inlet.
4. Place an external catch basin below the Water Pan drain hole.
RE-CIRCULATION
NOTE:
When using the re-circulation method, the water should be changed often for longer pump life.
(A)
Install the Drain Plug into the
Water Pan.
MK-2000 SETUP FOR OPERATION
CAUTION
In order to avoid breaker tripping, a 20-amp circuit breaker should be used.
NOTE:
Place the Water Pump in the back
of the Water Pan. Fill the Water Pan
until water completely covers the
Water Pump suction inlet.
1. Before powering or starting, check for damage that could prevent this
for binding and alignment of moving parts. Check for damaged, broken, or
missing parts.
2. Verify the On/Off switch is in the OFF position.
3. Before connecting the MK-2000 to a power supply, be sure the voltage, cycle
and phase of the job site power source meet the requirements of table below.
4. If using an extension power cord, make sure the length and wire gauge
correspond to the requirements listed in table on page 14. An extension
power cord that is too small in wire gauge (diameter), or too long in length,
will cause the motor to overheat and could cause premature failure.
5. Do not cover the motor vents as this could lead to motor overheating.
VOLTAGE:
CYCLE:
PHASE:
(B)
120v/230v
60hz
1-phase
20
WATER PUMP