Raymarine ST60 Compass Instrument Owner's Handbook Manual page 37

Hide thumbs Also See for ST60 Compass Instrument:
Table of Contents

Advertisement

Chapter 3: Installation
To fit a power cable:
1. Ensure the intended power source is switched off.
2. Run the power cable from the instrument to a suitable 12 V dc power source.
3. If the cable has not already been trimmed at the power supply end:
i. Cut the cable to length and trim back an appropriate amount of the outer
ii. Cut back and insulate the yellow wire.
4. Connect the screen to the power supply 0 V terminal.
5. Connect the red wire via a 3 A circuit breaker to the power supply +12 V ter-
minal.
6. Insert the power cable connector into one of the SeaTalk connectors at the
rear of the instrument.
12 V dc
supply
Power connections for stand-alone instrument
sheath.
3 A over-current
circuit breaker
Red
Screen
25
D4310-3