PARAMETERS
DESCRIPTION
PAR.
d0
Defrosting cycle activation.
d03
Start defrosting pressure.
End defrosting pressure.
d04
Min. time to start a defrosting cycle.
d05
Min. duration of a defrosting cycle.
d06
Max. duration of a defrosting cycle.
d07
d08
Delay between 2 defrosting cycle requests with in the same circuit.
d09
Defrosting delay between the 2 circuits.
Fan operating mode:
0= Always ON.
1=
F02
Depending on compressor (in parallel operating mode).
2= Depending on compressors in ON/OFF control.
3= Depending on compressors in speed control mode.
Temp. value for min. speed cooling.
F05
Pressure value for min. speed cooling.
Differential value for max. speed in cooling mode (temp).
F06
Differential value for max. speed in cooling mode (pres).
Fan shut-down differential in cooling mode (temp).
F07
Fan shut-down differential in cooling mode (pres).
Temperature value for min. speed in heating mode.
F08
Pressure value for min speed cooling.
Differential value for max. speed in heating mode (temp).
F09
Differential value for max. speed in heating mode (pres).
Fan shut-down differential in heating mode (temp).
F0
Fan shut-down differential in heating mode (pres).
F
Fan starting time.
Activation Low Noise:
0= Deactivate.
F5
1= Activate only in cooling mode.
2= Activate only in heating mode.
3= Activate both in cooling and heating mode.
Differential Low Noise in cooling mode.
F6
Differential Low Noise in heating mode.
F7
Maximum outdoor temperature with outdoor fan speed
regulation (over maximum speed)
F8
Activate remote change over:
H06
0= Deactivate.
1= Activate.
ON/OFF remoto:
0= Deactivate.
H07
1= Activate.
Serial address.
H0
H23
Activate Modbus.
H97
Expansion board software version.
H99
Software version.
Enable part load in high pressure:
0= Capacity control desactivated
1= Capactiy control activated for high pressure.
P04
2=Capacity control activated for low pressure.
3= Capacity control activated for high and low pres.
Configuration for digital input: 0= Not configurated
P09
10= winter/summer operation (PSW 66)
MIN. MAX. VAR. UD.
AIRCOOLAIR
Defrost
0


flag

D04
0.
bar
D03
/2
0.
bar
sec.
0
50

sec.
0
50

min.

50

0
50

min.
0
50

min.
Fan
 (ASC 00-40)  (KSCM 2D-24D)
0
3

int.
2 (ASH 00-40) 2 (KSHM 2D-24D)
3 (ASC/H 20-85) 3 (KSCM/HM 22E-86D)
-40
76
0.
ºC
/
/2
0.
bar
20 (F2=3) / 22 (F2=2) 20 (F2=3) / 22 (F2=2)
0
50
0.
ºC
0
30
0.
bar
0
50
0.
ºC
0
F5
0.
bar
-40
76
0.
ºC
12 (F2=3) / 22 (F2=2) 12 (F2=3) / 22 (F2=2)
/
/2
0.
bar
0
50
0.
ºC
0
30
0.
bar
0
50
0.
ºC
0
F8
0.
bar
0
20

0
3

flag
0
50
0.
bar
0
50
0.
bar
-40
76

ºC
Setting
0


flag
0


flag

200

ud.
0


flag
0
999

flag
0
999

flag
Alarms
0
3

flag
0
23

ud
2
BY DEFAULT
AIRCUBE
COMPACTAIR


5,4
5,7
30
30
60
60
0
0
8
8
35
40
0
0
28
28
2
2
6
6
0
0
2
2
30
30


0
0
3
3
0
0
0
0
5
5


30
30
0
0 (KSCM)  (KSHM)




0
0


0
0
FLATAIR


5,4
5,4
30
30
60
60
0
0
8
8
35
35
0
0


------
------
0
0
------
------
3
3
------
------
2
2
------
------
22
22
------
------
6
6
------
------
3
3
0
0
0
0
5
5


30
30
0
0




0
0


0
0