Overheat/Fan Fail:

When this LED flashes, it indicates a fan failure. When on continuously it indicates
an overheat condition, which may be caused by cables obstructing the airflow in
the system or the ambient room temperature being too warm. Check the routing of
the cables and make sure all fans are present and operating normally. You should
also check to make sure that the chassis covers are installed. Finally, verify that
the heatsinks are installed properly (see Chapter 5). This LED will remain flashing
or on as long as the indicated condition exists.
1

NIC1

Indicates network activity on the LAN1 port when flashing.
2

NIC2

Indicates network activity on the LAN2 port when flashing.

Heartbeat

On the 6038R-DE2CR16L, this is a serverboard heartbeat LED and indicates that
power is being supplied to the serverboard.
3-2

Power

Indicates power is being supplied to the system's power supply units. This LED
should normally be illuminated when the system is operating.
3-4

Drive Carrier LEDs

Each drive carrier has two LEDs:
Green: When illuminated, the green LED on the drive carrier indicates the drive
is powered on. If this LED is not lit, it means no power is being provided for the
drive. Please refer to Chapter 6 for instructions on replacing failed drives.
Red: A steady red LED indicates a drive failure. If one of the drives fails, you
should be notified by your system management software. Please refer to Chapter
6 for instructions on replacing failed drives. If this LED flashes ~ once per second
(1 Hz) it indicates RAID rebuilding activity.