9. Gently attached (2) Wires connected to spade terminals on base of lamp.
10. Replace the lamp cover back into place by securing (4) screws marked "A", "B",
"C", and "D".
11. Be sure to reset the LAMP HOURS in the system menu to prevent the protection
circuitry from accidently shutting off the lamp during normal operation.
12. If the lamp protection circuitry has already been initiated and the LAMP HOURS is
not reset, the "Replace the Lamp" warning will continue to flash and fixture will
eventually shut down. To reset LAMP HOURS, see instructions on the next page.