Technical Specifications - HP ProLiant ML350 Generation9 Quickspecs

Gen9
Table of Contents

Advertisement

QuickSpecs

Technical Specifications

System Unit
Tower Dimensions
Rack Dimensions
Tower Weight
Rack Weight
Input Requirements
(per power supply)
BTU Rating
Power Specifications
Power Supply Output
System Inlet
Temperature
DA - 15035 Worldwide QuickSpecs — Version 2 — 9.23.2014
HP ProLiant ML350 Generation9 (Gen9)
18.27 x 8.62 x 30.28 in (46.4 x 21.9 x 76.9 cm)
8.58 x 17.51 x 29.37 in (21.8 x 44.5 x 74.6 cm)
Minimum:
Maximum:
Minimum:
Maximum:
Range Line Voltage
Maximum
Rated Steady-State Power For 1400W Power Supply: 1400W (at 100 VAC),
Maximum Peak Power
Standard Operating
Support
66.14lb(30kg)
121.30lb (55kg)
57.3lb(26kg)
112.4lb(51kg)
100 to 120 VAC
200 to 240 VAC
For 800W Power Supply: 3207 BTU/hr (at 100
VAC), 3071 BTU/hr (at 200 VAC), 3112 BTU/hr (at
240 VAC) for China Only
For 500W Power Supply: 1979 BTU/hr (at 100
VAC), 1911 BTU/hr (at 200 VAC), 1965 BTU/hr (at
240 VAC) for China Only
1400W (at 240 VAC), 1400W (at 240 VAC)
For 800W Power Supply: 800W (at 100 VAC),
800W (at 240 VAC), 800W (at 240 VAC) input for
China only
For 500W Power Supply: 500W (at 100 VAC),
500W (at 240 VAC), 500W (at 240 VAC) input for
China only
For 1400W Power Supply: 1400W (at 100 to 127
VAC), 1400W (at 200 to 240 1VAC), 1400W (at 240
VAC) input for China only
For 800W Power Supply: 800W (at 100 to 127
VAC), 800W (at 200 to 240 1VAC), 800W (at 240
VAC) input for China only
For 500W Power Supply: 500W (at 100 to 127
VAC), 500W (at 200 to 240 VAC), 500W (at 240
VAC) input for China only
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 20°C/hr
(36°F/hr). The upper limit and rate of change may
be limited by the type and number of options
installed. For approved hardware configurations,
the supported system inlet range is extended to
be: 5° to 40°C (41° to 104°F) at sea level with an
altitude derating of 1.0°C per every 175 m (1.8°F
per every 574 ft) above 900 m (2953 ft) to a
maximum of 3050 m (10,000 ft). The approved
hardware configurations for this system are listed
at the URL:
www.hp.com/go/proliant/Ashrae
approved hardware configurations, the supported
system inlet range is extended to be: 5° to 45°C
(41° to 113°F) at sea level with an altitude
derating of 1.0°C per every 125 m (1.8°F per every
410 ft) above 900 m (2953 ft) to a maximum of
3050 m (10,000 ft). The approved hardware
configurations for this system are listed at the
For
Page 36