1.3 System sizing

To ensure the correct function of the system, it is
important that the pump is of the right type.
During operation, the CU 301 controls the pump
speed within the range from 3,000 rpm to 10,700
rpm, see fig. 6.
It is recommended to follow the guidelines below.
H [ft]
Pump curve
at 3,000 rpm
B
A
Pump curves at 3,000 rpm and
Fig. 6
10,700 rpm
A: Minimum head at no flow.
B: Maximum head at rated flow.
The following must be fulfilled:
• Minimum head at no flow < static head + system
pressure.
Comment: If this is not fulfilled, the pressure may
exceed the pressure set on the CU 301.
• Maximum head at rated flow > dynamic head +
system pressure.
Comment: If this is not fulfilled, the pressure may
fall below the pressure set on the CU 301.
Maximum head at rated flow and minimum head at
no flow can be found in the following sections.
Pump curve
at 10,700 rpm
Q
]
rated flow
Q [gpm

1.4 SQE and SQE-NE

Min. head
at 0 gpm,
Pump type
3,000 rpm
5 SQE-90
5 SQE-140
5 SQE-180
5 SQE-230
5 SQE-270
5 SQE-320
5 SQE-360
5 SQE-410
5 SQE-450
10 SQE-110
10 SQE-160
10 SQE-200
10 SQE-240
10 SQE-290
10 SQE-330
15 SQE-70
15 SQE-110
15 SQE-150
15 SQE-180
15 SQE-220
15 SQE-250
15 SQE-290
22 SQE-40
22 SQE-80
22 SQE-120
22 SQE-160
22 SQE-190
22 SQE-220
30 SQE-40
30 SQE-90
30 SQE-130
10 SQE-100 NE
10 SQE-140 NE
10 SQE-180 NE
10 SQE-220 NE
10 SQE-260 NE
10 SQE-300 NE
10 SQE-340 NE
22 SQE-40 NE
22 SQE-80 NE
22 SQE-110 NE
22 SQE-140 NE
22 SQE-180 NE
22 SQE-210 NE
Max. head
at rated flow,
10,700 rpm
[feet]
[feet]
12
104
18
161
24
218
31
275
37
332
43
389
49
446
55
503
61
560
12
102
17
158
23
214
29
270
34
326
40
382
10
80
4
121
19
161
24
202
29
242
33
283
38
323
5
35
9
75
14
115
18
155
23
195
27
235
5
31
11
78
16
125
10
96
15
134
20
173
25
212
30
251
34
290
39
329
35
290
39
322
42
353
46
385
50
417
54
448
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents