MaNTeL CLearaNCe
MaNTeL CLearaNCe
Finish the wall with material of your choice. do not install
a combustible mantel shelf less than 18" (457 mm)
from the top of the fireplace opening. do not install
a mantel face plate less than 6" (159 mm) from top of
fireplace opening. Figure 15. If a combustible material is
used below a flat mantel shelf, consult your local building
codes for minimum clearance from top of fireplace opening
to bottom of mantel shelf.
1 "
Ref.
* 18" from top of fireplace opening.
** 6" from top of fireplace opening. (Noncom-
bustible material must separate the black face
surround of the fireplace and any combustible
mantel material)
Figure 15 -
Combustible Mantel Clearances
87D0058
SB50HB Series Woodburning Fireplace
All joints (top, bottom and sides) where wall or decorative
facing material meets fireplace surround must be com-
pletely sealed with a noncombustible material. Figure 16
*
* *