MHSC KHLDV400 Installation And Operating Instructions Manual

Khldv series direct vent gas fireplace
Table of Contents

Advertisement

Models:
KHLDV400, KHLDV500, KHLDV600

Installation and operating Instructions

warnInG
IF tHe InForMatIon In tHeSe InStructIonS IS not
FoLLoweD exactLy, a FIre or expLoSIon May
reSuLt cauSInG property DaMaGe, perSonaL
Injury or LoSS oF LIFe.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
wHat to Do IF you SMeLL GaS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
warnInG: Improper installation, adjustment, alteration,
services or maintenance can cause injury or property
damage. refer to this manual. For assistance or additional
information consult a qualified installer, service agency
or the gas supplier.
this appliance may be installed in an aftermarket*,
permanently located, manufactured home (uSa only) or
mobile home, where not prohibited by local codes.
this appliance is only for use with the type of gas
indicated on the rating plate. this appliance is not
convertible for use with other gases, unless a certified
kit is used.
* aftermarket: completion of sale, not for purpose of resale, from the
manufacturer.
KHLDV Series
Direct Vent Gas Fireplace
730024
KHLDV cover
Due to HIGH teMperatureS, tHe appLIance
SHouLD Be LocateD out oF traFFIc anD
away FroM FurnIture anD DraperIeS.
cHILDren anD aDuLtS SHouLD Be aLerteD
to t H e H a Z a r D S o F H I G H S u r Fa c e
teMperature anD SHouLD Stay away to
aVoID BurnS or cLotHInG IGnItIon.
younG cHILDren SHouLD Be SuperVISeD
wHen tHey are In tHe SaMe rooM aS tHe
appLIance.
cLotHInG or otHer FLaMMaBLe MaterIaL
SHouLD not Be pLaceD on or near tHe
appLIance.
Keep tHe rooM area cLear anD Free FroM
coMBuStIBLe MaterIaLS, GaSoLIne, anD
otHer FLaMMaBLe VaporS anD LIquIDS.
InStaLLer: Leave this manual with the appliance.
conSuMer: retain this manual for future refer-
ence.
73D0024 9/10 Rev. 16

Advertisement

Table of Contents
loading

Summary of Contents for MHSC KHLDV400

  • Page 1: Installation And Operating Instructions

    KHLDV Series Direct Vent Gas Fireplace Models: KHLDV400, KHLDV500, KHLDV600 Installation and operating Instructions warnInG IF tHe InForMatIon In tHeSe InStructIonS IS not FoLLoweD exactLy, a FIre or expLoSIon May reSuLt cauSInG property DaMaGe, perSonaL Injury or LoSS oF LIFe.
  • Page 2: Table Of Contents

    KHLDV Series Gas Fireplace contentS thank you and congratulations on your purchase of an MHSc Fireplace. pLeaSe reaD tHe InStaLLatIon anD operatIon InStructIonS BeFore uSInG tHe appLIance! IMportant: read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Important Safety Information

    IMportant SaFety InForMatIon KHLDV Series Gas Fireplace owner InStaLLer Please retain these instructions for future reference. Please leave these instructions with the appliance. • read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. •...
  • Page 4: Code Approval

    KHLDV Series Gas Fireplace IMportant SaFety InForMatIon and coDe approVaL 12. Do not use this fireplace to cook food or burn paper or other objects. IMportant: 13. Never place anything on top of fireplace. pLeaSe reaD tHe FoLLowInG careFuLLy 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace.
  • Page 5: Product Features

    10.5” w.c. 13.0” w.c. KHLDV600PTSC 57,000 40,000 Manifold Pressure 3.5” w.c. 10.0” w.c. orifice Size Model Fuel Front rear KHLDV400 Nat. #49 (.073") #35 (.110" ) KHLDV400 #56 (.0465") #52 (.0635") KHLDV500 Nat. 2.3 mm #30 (.1285) KHLDV500 #55 (.052") #50 (.070")
  • Page 6: Fireplace & Framing Dimensions

    KHLDV Series Gas Fireplace FIrepLace and FraMInG DIMenSIonS Min. Rough Opening  Depth 1/2” or 5/8” P - Min. Rough Opening Width Min. Rough Opening Height Figure 2 - Fireplace and Framing Dimensions ref. KHLDV400 KHLDV500 KHLDV600 44ZB\zn" (1141 mm) 48ZB\zn" (1243 mm) 55" (1397 mm) 35Z\x" (902 mm) 39Z\x" (1003 mm) 45"...
  • Page 7: Pre-Installation Information

    pre-InStaLLatIon InForMatIon KHLDV Series Gas Fireplace BeFore you Start FIreBox FraMInG Read this homeowner manual thoroughly and follow all Firebox framing can be built before or after the appliance instructions carefully. Inspect all contents for shipping is set in place. Refer to Figure 2 for firebox dimensions damage and immediately inform your dealer if any damage and framing.
  • Page 8: Fireplace Location

    pre-InStaLLatIon InForMatIon KHLDV Series Gas Fireplace FIrepLace LocatIon Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e.
  • Page 9: Clearances

    cLearanceS KHLDV Series Gas Fireplace cLearanceS to coMBuStIBLeS Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. the appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
  • Page 10: Secure Fireplace

    KHLDV Series Gas Fireplace Secure FIrepLace to FLoor or FraMInG The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing.
  • Page 11: Venting Installation

    Installation of any damaged venting component. • Unauthorized modification of the venting system. • Installation of any component part not manufactured or approved by MHSC. • Installation other than permitted by these instruc- tions. FP2131 Failure to follow these instructions will void Figure 7 - the warranty.
  • Page 12: Installation Planning

    KHLDV Series Gas Fireplace VentInG InStaLLatIon InStaLLatIon pLannInG There are two basic types of direct-vent installation: never run the vent pipe down. this may cause • Horizontal Termination excessive temperatures which could cause • Vertical Termination a fire. It is important to select the proper length of vent pipe for the type of termination you choose.
  • Page 13: Termination Locations

    3. MHSC assumes no responsibility for the improper  only permitted if veranda, porch, deck or balcony is fully open on a performance of the appliance when the venting system minimum 2 sides beneath the floor: does not meet these requirements.
  • Page 14: How To Use The Vent Graph

    KHLDV Series Gas Fireplace VentInG InStaLLatIon terMInatIon cLearanceS For BuILDInGS wItH coMBuStIBLe anD noncoMBuStIBLe exterIorS G=6" (152mm) F=6" (152mm) Combustible – 6" (152 mm) Noncombustible – 2" (51mm) Inside Corner Outside Corner C = Maximum depth of 48" (1219mm) for alcove location D = Minimum width for back wall of alcove location Combustible - 38"...
  • Page 15: Vertical Sidewall Installation

    VentInG InStaLLatIon KHLDV Series Gas Fireplace VertIcaL SIDewaLL InStaLLatIon - Step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole lo- cation. Depending on whether the wall is combustible or noncombustible, cut opening to size.
  • Page 16: Vertical/Horizontal Termination Configurations

    KHLDV Series Gas Fireplace VentInG InStaLLatIon VertIcaL/HorIZontaL terMInatIon 36" conFIGuratIonS (914 mm) 24” Max. Since it is very important that the venting system main- (610 mm) tain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent con- figurations apply and must be strictly adhered to.
  • Page 17: Below Grade Installation

    VentInG InStaLLatIon KHLDV Series Gas Fireplace BeLow GraDe InStaLLatIonS 90° When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recom- mended. It allows installation depth down to 7" (178 mm) below grade level.
  • Page 18: Vertical Through-The-Roof Applications

    KHLDV Series Gas Fireplace VentnG InStaLLatIon Restrictor If the foundation Disc is recessed, use Figure 21 - recess brackets Install Restrictor Disc into Snorkel (not supplied) Fireplace Collar f o r s e c u r i n g Fireplace Foundation lower portion Collar...
  • Page 19: Installation For Vertical Termination

    VentInG InStaLLatIon KHLDV Series Gas Fireplace example: Elbow 1 90° For optimal flame appearance, a restrictor disk is necessary Elbow 2 45° on straight vertical runs of 10' of more. Elbow 3 45° • Runs may not incorporate elbows. Elbow 4 90°...
  • Page 20 KHLDV Series Gas Fireplace VentInG InStaLLatIon 4. Connect a section of pipe and extend up through the " hole. " note: If an offset is needed to avoid obstructions, you must support the vent pipe every three (3) feet. Use wall straps for this purpose.
  • Page 21: Fireplace Installation

    FIrepLace InStaLLatIon KHLDV Series Gas Fireplace cHecK GaS type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or con- version kit.
  • Page 22 KHLDV Series Gas Fireplace FIrepLace InStaLLatIon a manual shutoff valve must be installed only persons licensed to work with gas upstream of the appliance. union tee piping may make the necessary gas and plugged 1/8" npt pressure tapping connections to this appliance. point should be installed upstream of the appliance.
  • Page 23: Check Gas Pressure - Millivolt

    MILLIVoLt - cHecK GaS preSSure and eLectrIcaL InStaLLatIon KHLDV Series Gas Fireplace 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, Stop! Do not install the appliance.
  • Page 24: Remote Wall Switch Installation - Millivolt

    KHLDV Series Gas Fireplace MILLIVoLt - reMote waLL SwItcH InStaLLatIon reMote waLL MounteD SwItcH A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall OPTIONAL REMOTE switch in a junction box at the desired location on the WALL SWITCH wall.
  • Page 25 MILLIVoLt - optIonaL Fan/BLower SySteM KHLDV Series Gas Fireplace Blue Junction Box Blue Black Right  Hi-Temp Blower 120V AC 60Hz Black Hi-Temp T-Stat Sensor Factory Supplied Left  Blower Not Supplied junction Box White Figure 32 - Black Blower Junction Box Wiring Diagram Rheostat Figure 33 - Blower Wiring Diagram...
  • Page 26 MILLIVoLt - optIonaL Fan/BLower SySteM KHLDV Series Gas Fireplace Clip Firebox Wall FP2136 FP2137 Figure 36 - Figure 35 - Blower Access Covers Blower Access Covers FP2136 blower access plates FP2137 blower access plates Remove Solid Access Door FP2233 Replace with Louvered Access Door, Louvers Towards Bottom Figure 38 - FP2234...
  • Page 27: Operating Instructions - Millivolt

    MILLIVoLt - operatInG InStructIonS KHLDV Series Gas Fireplace For your SaFety reaD BeFore LIGHtInG If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. a. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly.
  • Page 28: Lighting Pilot

    MILLIVoLt - operatInG InStructIonS KHLDV Series Gas Fireplace LIGHtInG pILot For tHe FIrSt tIMe approVeD LeaK teStInG MetHoD If using a soap and water You may check for gas leaks with the following methods solution to test for leaks, only: Do not spray solution onto •...
  • Page 29: Lighting Burner

    MILLIVoLt - operatInG InStructIonS KHLDV Series Gas Fireplace LIGHtInG Burner MaIn Burner SwItcH The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob.
  • Page 30: Check Gas Pressure - Signature Command

    SIGnature coMManD - cHecK GaS preSSure and eLectrIcaL InStaLLatIon KHLDV Series Gas Fireplace 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply Pressure Inlet is different from the fireplace, Stop! Do not install the appliance.
  • Page 31: Junction Box Wiring

    eLectrIcaL InStaLLatIon KHLDV Series Gas Fireplace junctIon Box wIrInG 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° C wire in accordance with prevailing codes. 2. Remove the external junction box cover by removing the screw from the side of the outside firebox wall.
  • Page 32: Signature Command Wiring Diagram

    eLectrIcaL InStaLLatIon KHLDV Series Gas Fireplace Light 300 Watt To Outlet A/C Module Pilot Optional Blower 300 Watt Rear Burner Solenoid 300 Watt Max RF Receiver A/C Module ON/OFF Button Control Board Black / Thermopile Red / Thermopile Sensor Conversion NG/LP Ignitor / Sparker Plug-in Connector Control Board to Command Center note: Wall switch wires must OFF/LO ON/HI be connected together if a wall Master Switch switch is not being used.
  • Page 33: Fan/Blower Systems - Signature Command

    SIGnature coMManD - optIonaL Fan BLower SySteM KHLDV Series Gas Fireplace electrical Grounding Instructions: this electrical connections should only be appliance is equipped with a three-prong performed by a qualified licensed electrician. (grounding) plug for your protection against Main power supply must be turned off before shock hazard and should be plugged directly connecting the fan to the main electrical into a properly grounded three-prong...
  • Page 34: Signature Command

    SIGnature coMManD - operatInG InStructIonS KHLDV Series Gas Fireplace For your SaFety reaD BeFore LIGHtInG If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. a. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions.
  • Page 35: Operating Instructions

    SIGnature coMManD - operatInG InStructIonS KHLDV Series Gas Fireplace operatInG InStructIonS 1. Stop! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3.
  • Page 36: Product View And Features

    KHLDV Series Gas Fireplace SIGnature coMManD SySteM operatIon InStructIonS FeatureS To Thermopile RF Receiver ON/OFF To Sensor command center To Sparker • Easy Access Function Operation and System Configura- tion NG/LP • Operation Confirmation/Fault Diagnostic Indications Conversion (LED/Buzzer) • ON/OFF/HI/Med/Low Operation To Command Center •...
  • Page 37: System Configuration/Setup

    SIGnature coMManD SySteM operatIon InStructIonS KHLDV Series Gas Fireplace SySteM conFIGuratIon/Setup All System configuration/setup is done on the Command Center. note: When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center. Intermittent/Standing pilot Setup (Default intermittent) 1.
  • Page 38 KHLDV Series Gas Fireplace SIGnature coMManD SySteM operatIon InStructIonS FunctIonS/operatIon (with command center) turning on the fireplace 1. Turn on the master switch and wait for a beep. 2. Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High set- ting or last memory setting (See Turning Off Fireplace below).
  • Page 39: Touch Screen Remote Control Operation

    toucH Screen reMote controL operatIon KHLDV Series Gas Fireplace Due to the sensitive temperature monitoring components in the transmitter, it is necessary to allow the transmitter to stabilize to room tem- perature before accurate room temperatures are displayed. If the transmitter is activated from a severe cold condition, allow 15 minutes for accurate temperature readings to appear on the LcD display.
  • Page 40 KHLDV Series Gas Fireplace toucH Screen reMote controL operatIon Setting privacy code on transmitter: Battery Door Figure 51 The remote transmitter privacy code is preset in facto- ry. In the event of activation or interference from other nearby transmissions, change the code using the following procedures (learn function must be performed after changing the code):...
  • Page 41 toucH Screen reMote controL operatIon KHLDV Series Gas Fireplace c. Slide down on the arrow buttons to exit TIMER 1. Press the ON/up button to turn on the fireplace. The mode and shut off the fireplace. flame icon on the LCD displays High.
  • Page 42 toucH Screen reMote controL operatIon KHLDV Series Gas Fireplace is no manual flame height adjustment. The fan speed will 4. After the signal is sent, the ON/up and OFF/down but- also automatically adjust if turned on. tons become flame height controller again. 5.
  • Page 43: Safety Features

    toucH Screen reMote controL operatIon KHLDV Series Gas Fireplace 4. After the signal is sent, the On/up and Off/down but- n Safety Features tons become flame height controller again. 1. Low Battery Detection 5. When the light button is flashing, slide up and down on When low battery condition occurs, the transmitter will the arrow buttons will turn the light brightness to HIGH turn off the fireplace.
  • Page 44 KHLDV Series Gas Fireplace toucH Screen reMote controL operatIon n using the Mounting Base The transmitter comes with a mounting base which allows you to hang the transmitter on the wall. 1. Secure the mounting base on the wall with supplied screws.
  • Page 45: Glass Removal

    GLaSS reMoVaL KHLDV Series Gas Fireplace GLaSS FraMe reMoVaL 1. Remove the plate located in front of the glass at the bottom. 2. Remove rod provided for screen assembly located beneath the cover plate. 3. Rotate the access doors on the right and left side of the glass toward the glass. 4.
  • Page 46: Final Installation

    KHLDV Series Gas Fireplace FInaL InStaLLatIon BrIcK, LIGHt BuLB, anD LenS pLace- BrIcK, LIGHt BuLB, anD LenS pLace- Ment - 400/500 SerIeS Ment - 600 SerIeS 1. Remove the trapezoidal light shroud located at the back 1. Remove glass frame from fireplace. of the firebox by unfastening the three screws.
  • Page 47: Rock Wool Placement

    FInaL InStaLLatIon KHLDV Series Gas Fireplace rocK wooL pLaceMent - rocK wooL pLaceMent - 600 SerIeS 400/500 SerIeS Place rock wool evenly in dime-sized pieces over front burner both in front and behind grate. For the rear burner, 1. Place rock wool on the front burner to provide glowing place the rock wool only on the carry-over areas between embers.
  • Page 48: Log Placement 400/500 Series

    LoG pLaceMent KHLDV Series Gas Fireplace LoG pLaceMent - 400/500 SerIeS LG593 LG594 Burner Grate Assembly Step 1 1. Place the rear log over the grate toward the back by positioning the holes over the large pins located LG593 at the right and left. When the log is in place, the back surface of the log will come in contact with KHLDV grate LG594 the light trapezoid deflector.
  • Page 49: Log Placement

    LoG pLaceMent KHLDV Series Gas Fireplace 4. Place the middle log over the two burners by setting the flat surface over the burner and matching the indenta- tion located underneath the branch over the protrusion located at V-branch on the left front log placed in step #3. Rotate the right end of the log clockwise until it comes in contact with the reverse bend on the bracket located between the front and rear burner.
  • Page 50: Log Placement 600 Series

    KHLDV Series Gas Fireplace LoG pLaceMent rocK wooL pLaceMent - 600 SerIeS Place rock wool evenly in dime-sized pieces over front burner both in front and behind grate. For the rear burner, place the rock wool only on the carry- over areas between the flames.
  • Page 51 LoG pLaceMent KHLDV Series Gas Fireplace 3. Hold log #3 with the hole for the pin toward the back left corner. Position the log on the pin provided on the back left corner of the grate. Place the right end of the log in the notch provided on the back left corner of the grate.
  • Page 52 KHLDV Series Gas Fireplace LoG pLaceMent Log #6 6. Hold log #6 in your right hand with the charred detail to the right and the notches on the bottom. Position the log on top of the keys provided on the top of log #5 in the front and log #3 in the back.
  • Page 53: Cleaning And Maintenance

    cLeanInG anD MaIntenance KHLDV Series Gas Fireplace Sensor turn off gas before servicing fireplace. It is recommended that a qualified service Thermopile technician perform these check-ups at the beginning of each heating season Burner, pILot anD controL coMpart- Ment Signature command Keep the control compartment, logs, and burner areas System pilot...
  • Page 54: Venting System

    KHLDV Series Gas Fireplace cLeanInG anD MaIntenance VentInG SySteM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow.
  • Page 55: Troubleshooting

    trouBLeSHootInG KHLDV Series Gas Fireplace StanDInG pILot IGnItIon SyMptoM poSSIBLe cauSe actIon 1. Spark ignitor will A. Open door and check to make sure wire is connected to A. Wire disconnected. not light pilot after ignitor. repeated triggering of B. Check for spark at electrode and pilot. If no spark and B.
  • Page 56: Troubleshooting

    KHLDV Series Gas Fireplace trouBLeSHootInG StanDInG pILot IGnItIon SyMptoM poSSIBLe cauSe actIon 4. Frequent pilot A. Pilot flame may be too high A. Clean and adjust the pilot flame for maximum flame outage problem. or too low, causing pilot impingement on thermocouple. safety to drop out 5.
  • Page 57: Signature Command System

    trouBLeSHootInG KHLDV Series Gas Fireplace SIGnature coMManD SySteM ACTION OPERATION FAULT DIAGNOSIS Using Battery polarity wrong? Re-install batteries battery? Make sure Command Install batteries and/or Battery voltage low? Change batteries Center and plug in the AC board No beep in about the control 8 seconds board are...
  • Page 58: Replacement Parts

    KHLDV Series Gas Fireplace FIreBox coMponentS anD acceSSorIeS 12a,b 7a,b Item Description qty. KHLDV400 KHLDV500 KHLDV600 Bulb (100 Watt) 73D0020 73D0020 73D0020 730024 Bulb Socket 73D4521K 73D4521K 73D4521K KHLDV firebox parts Glass Frame Assembly 73D1015K 73D0159K 20300592 Junction Box Assembly (not shown)
  • Page 59: Standing Pilot Millivolt Control

    repLaceMent partS KHLDV Series Gas Fireplace StanDInG pILot — MILLIVoLt controL 11,12,13,14 730024 khldv mv valve parts 73D0024...
  • Page 60 MVWS Wall Thermostat Kit Forged Andiron 13" FA113 Cast Iron 12 " CAI121/2 Fuel conversion Kits - Millivolt control natural Gas to Lp KHLDV400 Kit #KHL400CKP KHLDV500 Kit #KHL500CKP Lp to natural Gas KHLDV400 Kit #KHL400CKN KHLDV500 Kit #KHL500CKN 73D0024...
  • Page 61: Signature Command System

    repLaceMent partS KHLDV Series Gas Fireplace SIGnature coMManD SySteM Venturi  400 Series Gasket Shield, Pilot 17, 18 Flex Hose 20H0022 Shield, Pilot Flex Hose Venturi 20H0022 Gasket 500 Series 17,18 600 Series Flex Hose 20H0022 73D0024...
  • Page 62 SCSACM SCSACM Solenoid (not shown) 73D3007 73D3007 73D3007 73D3007 20301204 20301204 Flame Baffle 20302747 20301814 accessories ref. Description qty. KHLDV400 KHLDV500 KHLDV600 Forged Andiron 13" FA113 FA113 Forged Andiron 16" FAI116 Cast Iron 12 " CAI121/2 CAI121/2 SCS Wall Extension Kit...
  • Page 63: Logs

    KHLDV Series Gas Fireplace LoGS KHLDV400 & KHLDV500 LoGS KHLDV600 LoGS Item Description qty. KHLDV400 KHLDV500 KHLDV600 Log #1 73D0539 73D0200 20301946 Log #2 73D0540 73D0201 20301947 730024 Log #3 73D0541 73D0202 20301948 600 log parts Log #4...
  • Page 64: Venting Components

    KHLDV Series Gas Fireplace repLaceMent partS VentInG coMponentS 730024 KHLDV vent parts 73D0024...
  • Page 65 KHLDV Series Gas Fireplace VentInG coMponentS For 5" 8" current Simpson Simpson Duravent Duravent qty./ or MHSc or MHSc Selkirk Item Box Description part no. part no. part no. Horizontal High Wind Termination Cap 58DVA-HC 1285 5DT-HC Horizontal Termination Cap w/Built-In Vinyl Siding Standoff, BHR8TK Heat Deflector, Firestop and Adjustable Pipe 7"...
  • Page 66: Massachusetts Residents Only

    KHLDV Series Gas Fireplace requirements for the commonwealth of of eight (8) feet above grade directly in line with the exhaust Massachusetts vent terminal for the horizontally vented gas fueled heating This product must be installed by a licensed plumber or appliance or equipment.
  • Page 67: Warranty

    MHSC in the appliance are found to be defective in materials or workmanship, MHSC will, at its option, replace or repair the defective components at no charge to the original owner. MHSC will also pay for reasonable labor costs incurred in replacing or repairing such components for a period of two years from date of installation.
  • Page 68: Efficiencies

    Recherchez dans la brochure KHLDV400PTSC 82.2 les caractéristique de rendement KHLDV500NV 75.2 énergétique de foyer au gaz KHLDV500PV 69.8 Énerguide KHLDV500NTSC 78.5 Selon CSA P.4.1-09 Based on CSA P.4.1-09 KHLDV500PTSC 71.8 KHLDV600NTSC 81.0 KHLDV600PTSC 80.0 MHSc 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...

This manual is also suitable for:

Khldv500Khldv600

Table of Contents