MHSC BBV400 Installation And Operating Instructions Manual

B-vent series natural vent gas fireplace

Advertisement

Quick Links

B-Vent Series
Natural Vent Gas Fireplace
Installation & Operating Instructions
Models:
BBV400, SBV400, SBV500
WARNING
IF THE INFORMATION IN THESE INSTRUCTIONS IS
NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF LIFE.
— Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WARNING: Improper installation, adjustment,
alteration, services or maintenance can cause
injury or property damage. Refer to this man-
ual. For assistance or additional information
consult a qualified installer, service agency or
the gas supplier.
624036
BBV SBV 400 cover
DUE TO HIGH TEMPERATURES, THE APPLI-
ANCE SHOULD BE LOCATED OUT OF TRAF-
FIC AND AWAY FROM FURNITURE AND DRAP-
ERIES.
CHILDREN AND ADULTS SHOULD BE ALERT-
ED TO THE HAZARDS OF HIGH SURFACE
TEMPERATURE AND SHOULD STAY AWAY TO
AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE SUPERVISED
WHEN THEY ARE IN THE SAME ROOM AS THE
APPLIANCE.
CLOTHING OR OTHER FLAMMABLE MATE-
RIAL SHOULD NOT BE PLACED ON OR NEAR
THE APPLIANCE.
KEEP THE ROOM AREA CLEAR AND FREE
FROM COMBUSTIBLE MATERIALS, GASO-
LINE AND OTHER FLAMMABLE VAPORS AND
LIQUIDS.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future refer-
ence.
62D4036 2/10 Rev. 11

Advertisement

Table of Contents
loading

Summary of Contents for MHSC BBV400

  • Page 1 B-Vent Series Natural Vent Gas Fireplace Installation & Operating Instructions Models: BBV400, SBV400, SBV500 WARNING IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PER- SONAL INJURY OR LOSS OF LIFE.
  • Page 2: Table Of Contents

    BBV, SBV Series Natural Vent Gas Fireplaces Thank you and congratulations on your purchase of an MHSC Fireplace Please read the Installation and Operation Instructions before using the appliance! IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Important Safety Information ...3 Code Approval ...4 Product Specifications...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION INSTALLER Please leave these instructions with the appliance. • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. • Any change to this fireplace or its controls can be dangerous. • Improper installation or use of this fireplace can cause serious injury or death from fire, burns, explosions, electrical shock and carbon monoxide poisoning. This fireplace is a decorative gas appliance. This fire- place must be properly installed by a qualified service person. CARBON MONOXIDE POISONING: carbon monoxide poisoning are similar to the flue with headaches, dizziness and/or nausea.
  • Page 4: Code Approval

    BBV, SBV Series Natural Vent Gas Fireplaces Continued on Page 4 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace. Use only the gas type indicated on rating plate. 15. This appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electri- cal Code, ANSI/NFPA 70 or the Canadian Electrical...
  • Page 5: Product Specifications

    PRODUCT FEATURES PRODUCT SPECIFICATIONS • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. • The appliance must be installed in accordance with local codes if any.
  • Page 6: Fireplace Framing

    43 " (1102 mm) 1/2" or 5/8"  Drywall  Spacers 16 ” (426 mm) Figure 2 - BBV400 Fireplace Dimensions and Framing Do not fill spaces around firebox with insulation or other materials. This could cause a fire. FIREPLACE DIMENSIONS & FRAMING Min. Rough ...
  • Page 7 FIREPLACE DIMENSIONS & FRAMING 1/2" or 5/8"  Drywall  Spacers 16 ” (426 mm) Figure 3 - SBV400, SBV500 Fireplace Dimensions and Framing Ref. For easier installation on SBV400 and SBV500 units, place gas supply pipe 6” to 8” inside unit. Measure from the center of the gas knock-out hole located at the bottom of the left side.
  • Page 8: Fireplace Location

    BBV, SBV Series Natural Vent Gas Fireplaces FIREPLACE LOCATION Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional acces- sories (i.e.
  • Page 9: Secure Fireplace

    SECURE FIREPLACE TO FLOOR OR FRAMING The fireplace must be secured to the floor and/or to framing studs as shown in Figure 5. Use two (2) wood screws or masonry/con- crete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing.
  • Page 10: Venting Installation

    “B” vent type pipe that has been listed by a nationally rec- ognized testing agency. Refer to B-Vent Pipe Sizing chart for proper elbow offset runs. B-Vent Pipe Sizing BBV400 SBV400 4” 6” Chimney centerline dimensions are referenced on Pages 6 &...
  • Page 11: Firestops

    VENT INSTALLATION FIRESTOPS • Locate chimney centerline dimension from a com- bustible back wall. Figures 2 & 3. Minimum firestop dimensions are found in the vent manufacturer’s in- structions. Clearances to combustibles may also be found on the sides of the flue sections. •...
  • Page 12: Outside Combustion Air

    BBV, SBV Series Natural Vent Gas Fireplaces NOTE: The use of outside air for combus- tion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of fireplace. Use model OAC4 combustion air kit (refer to Page 17).
  • Page 13: Combustion Air Assembly

    COMBUSTION AIR ASSEMBLY MODEL OAC-4 COMBUSTION AIR ASSEM- 1. Remove the cover plate from the 4” outlet opening location on the left outside of the fireplace. 2. Place starting collar (4”) into hole on left side of fire- place. Fireplace shortest side of air starting collar through fireplace outer wrap.
  • Page 14: Fireplace Installation

    BBV, SBV Series Natural Vent Gas Fireplaces CHECK GAS TYPE Use proper gas type for the fireplace you are installing. If you have conflicting gas types, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type.
  • Page 15: Fireplace Installation

    FIREPLACE INSTALLATION Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. NOTE: The gas line connection may be made using 1/2” rigid tubing or an approved flex con- nector. Since some municipalities have additional local codes, it is always best to consult your local authorities and the current edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54.
  • Page 16: Checking Gas Pressure

    BBV, SBV Series Natural Vent Gas Fireplaces 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately.
  • Page 17: Electrical Installation

    ELECTRICAL INSTALLATION ELECTRICAL WIRING Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city and state codes. The appliance, when installed, just be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70 (latest edi- tion) and Canadian Electrical Code, CSA C22.1.
  • Page 18: Electronic Pilot Ignition Wiring

    BBV, SBV Series Natural Vent Gas Fireplaces ELECTRONIC PILOT IGNITION WIRING Do not connect 110-120V AC to the Re- mote Wall Switch. The appliance will malfunction or destroyed. REMOTE WALL SWITCH Position the wall switch. Do not extend beyond the 15’ of wire. OPTIONAL DC REMOTE SYSTEMS These instructions replace the section entitled Hearth Mount in the Millivolt hand held remote in- structions supplied with the remote.
  • Page 19: Final Installation

    FINAL INSTALLATION ROCK WOOL PLACEMENT 1. Place rock wool on burner to provide glowing embers. For best results, pull the rock wool apart into pieces the size of a nickel or dime. 2. Distribute one layer of rock wool to cover the entire burner.
  • Page 20: Operating Instructions

    BBV, SBV Series Natural Vent Gas Fireplaces FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance is equipped with a pilot which must be lit with an ignitor while following these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
  • Page 21: Lighting Pilot

    OPERATING INSTRUCTIONS LIGHTING PILOT FOR THE FIRST TIME APPROVED LEAK TESTING METHOD You may check for gas leaks with the following methods only: • Soap and water solution • An approved leak testing spray • Electronic sniffer Never check for gas leaks with open flame! Check for gas leaks in each of the following locations: Pipe from the gas supply line connection to the gas valve...
  • Page 22: Lighting Burner

    BBV, SBV Series Natural Vent Gas Fireplaces MAIN BURNER SWITCH The “ON/OFF” switch for the main burner can be found behind the door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob.
  • Page 23: Lighting Electronic Ign

    OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance is equipped with an ignition device (Piezo) which automatically lights the pilot. Do NOT try to light the burner by hand. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
  • Page 24: Cleaning And Maintenance

    BBV, SBV Series Natural Vent Gas Fireplaces Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. BURNER, PILOT AND CONTROL COMPARTMENT Keep the control compartment, logs and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year.
  • Page 25: Vent System

    CLEANING and MAINTENANCE BBV, SBV Series Natural Vent Gas Fireplaces VENT SYSTEM The fireplace and venting system should be inspected before initial use and at least annually by a quali- fied field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow.
  • Page 26: Replacement Parts

    BBV, SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS FIREBOX COMPONENTS 62D4036...
  • Page 27: Logs

    Stainless Glass Door Assembly LOGS Item Description Rear Log - #1 Top Right Log - #2 Top Left Log - #3 62D4036 BBV, SBV Series Natural Vent Gas Fireplaces Qty. BBV400 61D0001 F400BBVW OAC4 GD36BA GD36PBA GD36SSA Qty. BBV400 LG664...
  • Page 28: Standing Pilot - Millivolt Control

    BBV, SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS STANDING PILOT - MILLIVOLT CONTROL 12, 13 62D4036...
  • Page 29 Wire Assembly Wire Assembly Spill Switch Accessories Remote Control On/Off wall Switch Kit Fuel Conversion Kits - Millivolt Natural Gas to LP BBV400 Kit # 400BBVCKP SBV400 Kit # 400SBVCKP SBV500 Kit # 500SBVCKP LP to Natural Gas BBV400 Kit # 400BBVCKN...
  • Page 30: Electronic Ignition

    BBV, SBV Series Natural Vent Gas Fireplaces ELECTRONIC IGNITION REPLACEMENT PARTS 62D4036...
  • Page 31 REPLACEMENT PARTS ELECTRONIC IGNITION Item Description Qty. Gas Valve Assembly Pilot Assembly Burner Tube Flexhose with Shut-off Valve Rocker Switch Injector Burner Assembly Venturi Wire Assembly Ignition Module Transformer Spill Switch 62D4036 BBV, SBV Series Natural Vent Gas Fireplaces BBV400NV BBV400PV SBV400NV 37D0016...
  • Page 32: Troubleshooting

    BBV, SBV Series Natural Vent Gas Fireplaces STANDING PILOT IGNITION SYMPTOM POSSIBLE CAUSE 1. Spark igniter A. Wire disonnected. will not light pi- lot after repeat- B. Defective igniter. ed triggering of piezo. C. No gas or low gas pressure. D.
  • Page 33: Troubleshooting

    TROUBLESHOOTING ELECTRONIC IGNITION START 1. Turn gas supply off. 2. Turn ON/OFF switch to “ON” Power to module (24V Normal) Is there a spark across ignitor sensor gap? Turn on gas. Does pilot burner light? Does spark stop when pilot is lit? Does main burner light? Does system run until ON/OFF switch is in “OFF”...
  • Page 34 BBV, SBV Series Natural Vent Gas Fireplaces GENERAL TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE 1. Glass soots. A. Flame impingement on logs. A. Too much offset. 2. Poor draft due to venting. B. Too many elbows. C. Vent height too short. D. Vent too close to roof line.
  • Page 35 BBV, SBV Series Natural Vent Gas Fireplaces 62D4036...
  • Page 36 BBV, SBV Series Natural Vent Gas Fireplaces 62D4036...
  • Page 37 BBV, SBV Series Natural Vent Gas Fireplaces 62D4036...
  • Page 38 Massachusetts Residents Only — Please read and follow these special requirements BBV, SBV Series Natural Vent Gas Fireplaces NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Any residence with a direct vent product must have a CO detector installed in the residence.
  • Page 39: Warranty

    BBV, SBV Series Natural Vent Gas Fireplaces LIMITED LIFETIME WARRANTY POLICY LIFETIME WARRANTY The following components are warranted for life to the original owner, subject to proof of purchase; Firebox, Combus- tion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. FIVE YEAR WARRANTY The following components are warranted for five (5) years to the original owner, subject to proof of purchase;...
  • Page 40 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...

Table of Contents