Clearances; Clearances To Combustibles; Mantel Clearances - MHSC CDVR33n/pv7 Installation And Operating Instructions Manual

Direct vent gas fireplace
Table of Contents

Advertisement

CleaRanCeS

CleaRanCeS To CoMBuSTIBleS

Follow these instructions carefully to
ensure safe installation. Failure to follow
instructions exactly can create a fire
hazard.
The appliance cannot be installed on a
carpet, tile or other combustible material
other than wood flooring. If installed on
carpet or vinyl flooring, the appliance
shall be installed on a metal, wood or
noncombustible material panel extending
full width and depth of the appliance.
72" 
Minimum
Side
Wall
6"
Minimum
Figure 5 -
Ceiling and Side Wall Clearances

ManTel CleaRanCeS

fP2032
wall clearances
noTe: The combustible area above the facing must
not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
never obstruct or modify the air inlet or
outlet grilles (louvers). This may create
a fire hazard.
20301835
CDVSC7 & CDV7 Series Gas Fireplace
Finish Wall
W
A
Top of Heat
Exhaust Vent
CDV33/42/47
Side View
Ref.
CDV33
A 14" (356 mm) 12" (305 mm) W 12" (305 mm) 12" (305 mm)
B 11" (279 mm) 9Z\x" (241 mm) X
C 10" (254 mm) 8Z\x" (216 mm) Y
D
8" (203 mm)
Finish Wall
12" (305 mm)
13"
(330 mm)
Top of Heat
Exhaust Vent
CDV36
Side View
FP2032
FP2286
Side of Fireplace
Opening
Figure 6 -
Mantel Clearances
Stud
Header
X
Y
B
Z
C
D
noTe: CDVR33SC7 has no standoffs.
CDV42/47
Ref.
CDV33
8" (203 mm) 8" (203 mm)
FP2285b
mantel clearances
6" (152 mm) 6" (152 mm)
6" (152 mm)
Z
2Z\x" (64 mm) 2Z\x" (64 mm)
Stud
Header
2 "
(64 mm)
12"
(305 mm)
Stud
FP2285 36
mantel clearances
1"
1 "
3 "
2 "
3"
5"
6"
Front View
FP2286
Mantel leg clear
Standoff
FP2285b
CDV42/47
Standoff
FP2285
Wall
Combustible
Material Area
4 "
45°
11

Advertisement

Table of Contents
loading

Table of Contents