Clearance And Height Requirements; Hearth Dimensions - MHSC 36STFL Installation And Operating Instructions Manual

Lo-rider designer vent-free fireboxes
Table of Contents

Advertisement

CLEARANCES and HEIGHT REqUIREMENTS
Ensure that minimum clearances shown in Figures 3
through 7 are maintained. Left and right clearances are
determined when facing the front of the firebox.
Follow these instructions carefully to ensure safe instal-
lation. Failure to follow these requirements may create a
fire hazard.
1. Sidewall Clearances — The clearance from the inside
of the appliance to any combustible adjacent wall should
not be less than 5B\,". Figure 3
. Ceiling Clearance — The ceiling must be at least 4"
from the top of the firebox opening (bottom of hood).
Figure 3
3. Back Wall Clearance — The appliance may be placed
against a combustible back wall.
4. Parallel Wall Clearance — The clearance from the
opening of the firebox to any wall that is parallel to the
opening should not be less than 36" (36STFL and 36PFL
models only). Figure 4
5 "
Figure 3 -
Sidewall and Ceiling Clearances
79D0007
42"
FP886
FP2886
see thru clearances
FP887
Figure 4 -
Parallel Wall Clearance
(LSTF36 and LPF36 Models Only)
FP2887
parallel clearances
C
A
A
See-thru
33C\zn"
FP2888
Corner
35C\zn"
hearth dims
Peninsula
35C\zn"
Figure 5 -

Hearth Dimensions

Lo-Rider Vent Free Fireboxes
36"
B
B
C
1ZB\zn"
7C\v"
1ZB\zn"
7C\v"
1ZB\zn"
7C\v"
7