The following chart illustrates the information (related to the alarms HACCP) that the device is able to
memorize.
Alarm
alarm temperature blast
chilling or temperature
blast freezing not
concluded within the
maximum duration
maximum temperature
alarm during the
maintenance
alarm stop feeding
during the conservation
phase
To avoid a continuous memorizing of feeding interruption alarms (code "PF"), please make sure the device is in
the state "stand-by" or in the state "on" before the feeding.
If the duration of the feeding interruption alarm (code "PF"), causes the clock error (code "rtc"), the device will
not memorize the date, the time when the alarm starts, or the duration of the alarm.
The LED HACCP gives information about the alarms HACCP memory state; please consult the paragraph 10.1
"signals."
Please operate in the following way:
1.
2.
3.
4.
5.
6.
Distributed By:
Code
Critical Value
the temperature blast
freezing not concluded
Time
within the maximum
duration
cell maximum
AH
temperature during the
cell temperature during
PF
the feeding restore
9ii: ALARMS HACCP INFORMATIONS DISPLAY
Make sure that the keyboard is not jammed and that a procedure is not in progress.
Keep the DOWN key pressed for 1 second. The display will show the first available label.
Press and release the UP or DOWN key to select "LS"
Press and release the BLAST CHILLING key. The display will show the code of the most
recent alarm or one of the codes from chart 10.1 "Preliminary Instructions", followed by
number "1" (the greater the number, the older the alarm).
Press and release the UP or DOWN key to select an alarm code (for example "AH3")
Press and release the BLAST CHILLING key: the LED HACCP will stop flashing and remain
permanently on. For example, the display will show, the following information in sequence:
Date and hour of
event
alarm
Street:5C Wendy Ct. Greensboro, NC 27409▪Mailing: PO Box 18542,
Greensboro, NC 27419▪P:336-856-2919▪F:336-217-8838
Email:Sales@AdvancedGourmet.com▪Web:www.AdvancedGourmet.com
Duration
from 1 min to 99 h and
yes
59 min, partial if the
alarm is in progress
from 1 min to 99 h and
59 min, partial if the
yes
alarm is in progress
from 1 min to 99h and 59
yes
min
P a g e | 16
Need help?
Do you have a question about the JOF ONE and is the answer not in the manual?