4 Configuration
Energy metering
#
Code
[A.2.2.8]
[D-08]
Optional external kWh meter 1:
▪ 0 (No): NOT installed
▪ 1: Installed (0.1 pulse/kWh)
▪ 2: Installed (1 pulse/kWh)
▪ 3: Installed (10 pulse/kWh)
▪ 4: Installed (100 pulse/kWh)
▪ 5: Installed (1000 pulse/kWh)
[A.2.2.9]
[D-09]
Optional external kWh meter 2:
▪ 0 (No): NOT installed
▪ 1: Installed (0.1 pulse/kWh)
▪ 2: Installed (1 pulse/kWh)
▪ 3: Installed (10 pulse/kWh)
▪ 4: Installed (100 pulse/kWh)
▪ 5: Installed (1000 pulse/kWh)
4.2.4
Quick wizard: Capacities (energy
metering)
#
Code
[A.2.3.1]
[6-02]
Booster heater capacity [kW]
[A.2.3.6]
[6-07]
Bottom plate heater capacity [W]
4.2.5

Space heating/cooling control

Leaving water temperature: Main zone
#
Code
[A.3.1.1.1]
N/A
Set point mode:
▪ 0 (Absolute): Absolute
▪ 1
Weather‑dependent
▪ 2 (Abs + scheduled): Absolute +
scheduled (only for leaving water
temperature control)
▪ 3
Weather‑dependent
(only for leaving water temperature
control)
[A.3.1.1.3]
[1-00]
Weather‑dependent curve (heating):
[1-01]
T t
[1-02]
[1-03]
[1-02]
[1-03]
▪ T
(main)
▪ T
Installation manual
14
Description
Description
Description
(Weather
dep.):
(WD
+
scheduled):
+
scheduled
[1-00]
[1-01]
: Target leaving water temperature
t
: Outdoor temperature
a
#
Code
[A.3.1.1.4]
[1-06]
[1-07]
[1‑08]
[1-09]
Leaving water temperature: Additional zone
#
Code
[A.3.1.2.1]
N/A
[A.3.1.2.3]
[0-00]
[0-01]
[0-02]
[0-03]
[A.3.1.2.4]
[0-04]
[0-05]
[0-06]
[0-07]
T a
Description
Weather‑dependent curve (cooling):
T t
[1-08]
[1-09]
[1-06]
[1-07]
▪ T
: Target leaving water temperature
t
(main)
▪ T
: Outdoor temperature
a
Description
Set point mode:
▪ 0 (Absolute): Absolute
▪ 1
(Weather
Weather‑dependent
▪ 2 (Abs + scheduled): Absolute +
scheduled (only for leaving water
temperature control)
▪ 3
(WD
+
Weather‑dependent
+
(only for leaving water temperature
control)
Weather‑dependent curve (heating):
T t
[0-01]
[0-00]
[0-03]
[0-02]
▪ T
: Target leaving water temperature
t
(additional)
▪ T
: Outdoor temperature
a
Weather‑dependent curve (cooling):
T t
[0-05]
[0-04]
[0-07]
[0-06]
▪ T
: Target leaving water temperature
t
(additional)
▪ T
: Outdoor temperature
a
EHVH/X04+08+16S18CA + EHVH/X08+16S26CA
Daikin Altherma - Low Temperature Split
4P313772-1D – 2012.12
T a
dep.):
scheduled):
scheduled
T a
T a

Advertisement