as electricity. The primary energy factor for natural gas is 1.
Assuming an average electricity production efficiency (including
transportation losses) of 40%, the primary energy factor for
electricity equals 2.5 (=1/0.40). The primary energy factor allows you
to compare 2 different energy sources. In this case, the primary
energy use of the heat pump is compared to the natural gas use of
the gas boiler.
#
Code
N/A
[7‑03]
Compares the primary energy use of the
heat pump with that of the boiler.
Range: 0~6
INFORMATION
▪ The primary energy factor can always be set, but is
only used in case the savings mode is set to
Ecological.
▪ To set electricity price values, do NOT use overview
settings. Set them in the menu structure instead
([7.4.5.1], [7.4.5.2], and [7.4.5.3]). For more information
on how to set the energy prices, see the operation
manual and the user reference guide.
INFORMATION
Solar panels. If solar panels are used, set the electricity
price value very low to promote the use of the heat pump.
6.2.4
Quick wizard: Capacities (energy
metering)
#
Code
[A.2.3.6]
[6-07]
Bottom plate heater capacity [W]
6.2.5

Space heating control

Leaving water temperature: Main zone
#
Code
[A.3.1.1.1]
N/A
Set point mode:
▪ 0 (Fixed): Absolute
▪ 1
dependent
▪ 2
scheduled (only for leaving water
temperature control)
▪ 3
dependent + scheduled (only for
leaving water temperature control)
[7.7.1.1]
[1‑00]
Weather-dependent curve (heating):
T t
[1‑01]
[1‑02]
[1-02]
[1‑03]
[1-03]
▪ T
(main)
▪ T
EJHA04AAV3
Daikin Altherma hybrid monobloc – Heat pump module
4P530607-1B – 2018.10
Description
Description
Description
(Weather
dep.):
Weather-
(Fixed/scheduled):
Absolute
(WD/scheduled):
Weather-
[1-00]
[1-01]
: Target leaving water temperature
t
: Outdoor temperature
a
INFORMATION
In order to optimise comfort as well as running costs, it is
recommended to choose weather-dependent setpoint
operation. Set the settings carefully; they have significant
influence on heat pump as well as boiler operation. Too
high leaving water temperature can result in constant boiler
operation.
Pump control
*HY2KOMB28+32AA gas boiler
a
a Main pump (= inside the gas
boiler)
If...
Space heating is done
by...
Outdoor unit only
Gas boiler only
(only applicable in case of
*HY2KOMB28+32AA gas boiler)
Combination of outdoor unit and
gas boiler
(only applicable in case of
*HY2KOMB28+32AA gas boiler)
If the pump runs according to ΔT control:
If Emitter type [2-0C]=...
0: Underfloor heating
1: Fancoil unit
2: Radiator
INFORMATION
+
Changing these settings can result in discomfort. Refer to
the installer reference guide for more information.
Leaving water temperature: Modulation
#
Code
[A.3.1.1.5]
[8‑05]
T a
6 Configuration
Third-party gas boiler
a
a Main pump (= external pump)
Then the main pump runs...
And...
[C-0B]=1 According to ΔT control (see
below).
[C-0B]=0 At maximum pump speed.
At maximum pump speed.
Then the target ΔT in heating
is...
Variable according to [1-0B].
Fixed (10°C).
Description
Leaving water temperature modulation:
▪ 0 (No): Disabled
▪ 1 (Yes): Enabled. The leaving water
temperature is calculated according
to the difference between desired
and actual room temperature. This
allows
better
matching
heat  pump
capacity
to
required capacity and results in less
start/stop cycles of the heat  pump
and more economic operation.
Installation manual