Safety Data Sheet Océ 3145 Digital Copier - Canon oce 31x5e Daily Maintenance

Table of Contents

Advertisement

Safety data sheet Océ 3145 Digital Copier
PRODUCT SAFETY DATA SHEET
Model
Description
Max. process speed
Dimensions
Weight
Voltage
Frequency
Current-rated
Current-max
Power consumption, operation
Power consumption, standby
Mains connection
Safety class
Protection class
Sound pressure level
(at operator/bystander
position)
Sound power level
Radio interference
Radiation
Heat emission
Ozone emission
Room volume
Room ventilation
Use simulation at random
operation
Consumables
Additional safety information
Copyright © 1999 Océ-Technologies B.V., Venlo, NL
The content of this safety data sheet is subject to the disclaimer of liability on page 103 of this manual.
104
Océ 31x5E Copy jobs & daily maintenance
Océ 3145 DC
Electrostatic digital copier, console model, plain paper, organic photoconductive belt,
powder toner, automatic duplexing.
46 A4 copies/min or 23 A3 copies/min
Width
1622 mm
Depth
885 mm
Height
1280 mm
413 kg
120 V
60 Hz
16 A
20 A
2000 W
560 W
Cable with plug
I
(IEC 536) Protective earth connection
IP 20
(IEC 529)
Standby:
38 dB(A)
49 dB(A)
Complies with FCC r ules and regulations, part 15 class A
Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)
Standby 560 W ; in operation 2000 W
0,01 mg/min at continuous operation
Recommendation: min. 30 m
Recommendation: min. 15 m
For heat evacuation extra ventilation may be necessary.
Room v olume and ventilation as recommended
Daily copy volume (much more than average)
Total worktime
Ozone concentrations:
- Time weighted average
- Peak
Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone
Odour Perception Limit for ozone
Océ Master (Océ Material Safety Data Sheet E-193)
Océ F11 Toner (Océ Material Safety Data Sheet E-212)
Océ Copying Materials
This apparatus is suitable for processing recycling paper which complies with the
requirements of ENV 12281.
The ozone Þlter does not have to be replaced for keeping the ozone concentration in the
workplace below 0,04 mg/m (the life of the Þlter equals that of the apparatus).
Listed according to standard UL 1950 and CAN/CSA-C22.2 No.950
208 V
220-240 V
60 Hz
60 Hz
9,8 A
9,2-8,8 A
14 A
14 A
In operation:
mainbody 59 dB(A);
incl. optionals 60 dB(A);
impulse ∆ L
= 5 dB(A)
i
mainbody 72 dB(A); incl. optionals 74 dB(A)
3
3
/h (natural ventilation)
7500 A4
8 h
0,001 mg/m
0,003 mg/m
0,2 mg/m
0,04 mg/m
3
LISTED 927F
INFORMATION
TECHNOLOGY
EQUIPMENT
E 69871
Number
E-704-a-US
Date
July 1999
3
(0.0005 ppm)
3
(0.0015 ppm)
3
(0,1 ppm)
3
(0,02 ppm)