Summary of Contents for Salus it500
Page 1
Internet Thermostat I N S TA L L E R M A N U A L...
Page 2
1. Product compliance & safety information These instructions are applicable to the SALUS Controls model stated on the front cover of this manual only, and must not be used with any other make or model. This accessory must be tted by a competent person, and installation must comply with the guidance provided in the current IEE Wiring Regulations and current Building Regulations.
Page 3
Wire up the receiver using one of the Clip the front of the unit back on by aligning the Securely screw the front of the receiver in place. schematics on pages 4 and 5 ttings and pushing into place. iT500 Installer Manual 03...
Page 4
230V OV - 230v OV 230 230V Switching - Combination Boiler One central heating zone only. BOILER BOILER One central heating zone only. Two central heating zones. 230V 230V iT300 Sensor required for this con guration. 04 iT500 Installer Manual...
Page 5
2 x CH Zones - 230 V Switching Combination Boiler One central heating zone plus hot water. Two central heating zones. 230V iT300 Sensor required for this con guration. 230V 230V BOILER BOILER One central heating zone plus hot water. Permanent iT500 Installer Manual 05...
Page 6
After rst ensuring that the bracket is Once clipped into place, ensure the unit is suitable wall using the ttings supplied secure, clip the iT500 into place by securely seated on the bracket. and the built in level. aligning the recess on the back of the unit For best results mount the to the bracket and clipping into place.
Page 7
6. Connecting the Gateway to your existing router Flashing red light on setup. Constant green light when the iT500 is connected to the SALUS Controls Server. iT500 Installer Manual 07...
Page 8
Insert the second battery supplied into the left Ensure the batteries are tted securely Replace the battery cover to the hand side of the base of the iT500 Thermostat. in the base of the iT500 Thermostat. base of the iT500 Thermostat.
Page 9
8. Setting up the iT500 Thermostat After powering up iT500 for the rst time the display will go through the following sequence. OTA* Revision number The globe icon will appear when the unit automatically connects to the internet via the SALUS iTG500 Gateway.
Page 10
Indicates touch lock is activated Battery status Indicates battery is low Holiday indicator Indicates holiday operation mode is selected Internet indicator Indicates connection to iTG500 and SALUS server Cooling indicator Indicates cooling output is on* ON indicator Hot water continuously on* Once indicator...
Page 11
Selecting your system con guration Based on your system wiring on page 4. If the iT500 is to be used in the UK for single zone heating then there is no need to enter system con guration setup, please proceed to page 15.
Page 12
Centigrade to Fahrenheit Centigrade to Fahrenheit GMT Time setting** GMT Time setting** GMT Time setting** 12 iT500 Installer Manual * Cooling can only be selected if your system supports this. ** Please refer to the following page for your region.
Page 13
GERMANY SWEDEN CYPRUS BELARUS* ICELAND* CZECH NORWAY GREECE FINLAND SPAIN MALTA ROMANIA MOLDOVA FRANCE CROATIA RUSSIA LATVIA ITALY SERBIA UKRAINE SWITZERLAND BOSNIA The countries marked with * do not LUXEMBOURG SLOVENIA iT500 Installer Manual 13 observe Daylight Saving Time HOLLAND...
Page 14
Now that you have selected your system con guration you can continue with the rest of the installation setup. DST (daylight saving time) ON will automatically change your time from summer to winter. 11. Pairing the iT500 with the iT500RX Receiver 14 iT500 Installer Manual...
Page 15
Now go to the iT500 Thermostat. screen sequence shown on the next page. When the iT500RX Receiver and the iT500 Thermostat are paired then the light will be green. FAILSAFE MODE: In the event of RF signal loss, your system will be Press switched on for 4 minutes, then o for 11 minutes.
Page 16
Attach the wall mounting bracket to a Align the grooves on the back of the iT300 Once in place, ensure the unit is securely suitable wall using the ttings supplied. unit and slide onto the bracket. seated on the bracket. 16 iT500 Installer Manual...
Page 17
2 seconds. The iT500 has successfully paired with the iT300 when the antenna stops ashing. Press to return to home screen.
Page 20
Enter the iT500 STA number (Please refer to page 8). Then press REGISTER. Your iT500 will appear as above and is now ready to be controlled or viewed via your PC or Smartphone. Just click on the iT500 icon on your PC.
Page 21
Once you have registered your iT500 online you can also download the smartphone App from the iPhone App Store or the Android App Store depending on which kind of Smartphone you are using. Find the iT500 App on the App Store and click download. The App will automatically download to your Smartphone and once downloaded you can begin controlling your iT500 Thermostat.
Page 22
16. Adding or renaming the iT500 in your device list Enter your user ID and password. When you rst open the iT500 App If you add more than 1 iT500 to your If you forget your password, follow Press your iT500 will appear in the device device list, you may wish to rename the on screen instructions.
Page 23
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its speci cation, for a period of two years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
Page 24
TECHNICAL: T: +44 0 1226 323961 E: tech@salus-tech.com www.salus-controls.com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change speci cation, design and materials of products listed in this brochure without prior notice.
Need help?
Do you have a question about the it500 and is the answer not in the manual?
Questions and answers