Problem
Steam suddenly es‐
capes from the appli‐
ance door.
...
Possible cause and remedy
The safety valve has tripped.
Proceed as described in "Safety features - Pres‐
sure release / Safety valve".
The pressure release has tripped.
Proceed as described in "Safety features - Pres‐
sure release / Safety valve".
The door seal is not sitting correctly or is damaged,
e.g. cracks are visible.
Fit the seal correctly or replace it with a new one.
With all fault messages:
The door can only be opened when
- the fault message is flashing alternately with the set
temperature,
- the symbol is flashing in the time display,
- the buzzer has stopped.
If the display is not flashing, the appliance is still pro‐
cessing the fault.
The temperature sensor is defective.
Switch the appliance off and call Miele.
Water is not getting into the appliance.
The tap has been turned off.
Turn it on and start the programme again.
The water inlet hose is faulty.
Switch the appliance off, turn off the water supply
at the tap and call Miele.
The filter in the water inlet is blocked.
Clean the filter.
If you cannot remedy the fault yourself, switch the
appliance off and call a plumber or Miele.
Problem solving guide
83