Braeburn 5020 Detailed Installer Manual page 13

Single stage heat / cool conventional or heat pump
Hide thumbs Also See for 5020:
Table of Contents

Advertisement

15 AC Power Interrupt Warning
when AC power to the thermostat is lost.
16 Short Cycle Protection
out after turning off. This short cycle protection is also active in the heat mode if a heat pump system was
selected in Option 6.
17 Residual Cooling Fan Delay
has turned off. This delay will help remove the remaining cool air out of the ductwork providing additional
efficiency.
18 Adaptive Recovery Mode (early recovery)
mode) feature. During ARM, room temperature is recovered by turning on the heating or cooling before the
end of the set back period. The set point temperature is changed to that of the upcoming program temperature.
19 Indoor Remote Sensor Control
installation, the thermostat will automatically detect the sensor. When an indoor sensor is detected, you may
select between thermostat only (I SENS), remote sensor only (E SENS) or combining the thermostat and the
remote sensor (A SENS). NOTE: This option does not apply to a Braeburn outdoor sensor. When an outdoor
sensor is connected the thermostat automatically recognizes it and no further configuration is necessary.
20 Lockout Security Level – Selects the level of keypad lockout when the thermostat is locked. Level 2 locks
the entire thermostat (including the front reset button). Level 1 locks everything except the SpeedBar
allowing for up and down temperature adjustment. NOTE: The lock code is set in the User Settings mode
(see User Manual).
21 Auto Changeover Dead Band
selected, the system automatically switches between heating and cooling when the room temperature
meets the normal criteria for either a heating or cooling call. There is a forced separation (dead band)
between the heating and cooling set points so that the systems do not work against each other. This
option selects the amount of this dead band in degrees with the default being 3° F.
22 Compressor Balance Point
outside air temperature is less than the selected setting of 15° F to 50° F (-9° C to 10° C)
23 Auxiliary Heat Balance Point
outside air temperature exceeds the selected setting of 70° F to 40° F (21° C to 4° C). NOTE: This balance
point overrides the fossil fuel compressor lockout in option 13. If this option is set to gas and the outdoor
temperature is over the auxiliary balance point, the compressor will remain on during a call for auxiliary heat.
24 Heat Set Point Upper Limit – Selects the heating set point upper adjustment limit.
25 Cool Set Point Lower Limit
[note
6] – When enabled, the thermostat will display an outage warning
[note
7] – Selects the number of minutes the cooling compressor will be locked
[note
7] – Selects a delay for the system fan after the cooling compressor
[note
[note
9] – If a Braeburn
[note
10] – When auto changeover mode is enabled in option 5 and
[notes 4,
11] – Locks out the use of the compressor heat stage when the
[notes 4,
11] – Locks out the use of the auxiliary heat stage when the
[note
7] – Selects the cooling set point lower adjustment limit.
8] – Enables or disables the ARM
indoor remote sensor is connected during
®
13
(adaptive recovery
TM
®
Installer Guide