Installation Site Instructions
A proper installation site is vital for correct and efficient
operation of the unit. Avoid the following sites where:
strong heat sources, vapours, flammable gas or volatile
liquids are emitted.
high-frequency electro-magnetic waves are generated
by radio equipment, welders or medical equipment.
salt-laden air prevails (such as close to coastal areas).
the air is contaminated with industrial vapours and oils.
the air contains sulphurous gas such as in hot spring
zones.
corrosion or poor air quality exists.
Installation Site of Indoor Unit
1
The air inlet and outlet should be away from the
obstructions. Ensure the air can be blown through the
whole room.
2
Select a site where the condensing water can be
easily drained out, and where it is easily connected for
the outdoor unit.
3
Select a place where it is out of reach of children.
4
Select the place where the wall is strong enough to
withstand the full weight and vibration of the unit.
5
Be sure to leave enough space to allow access for routine
maintenance. The installation site should be 2m or more
above the floor.
6
Select a place about 1m or more away from a TV set or
any other electric appliance.
7
Select a place where the filter can be easily taken out.
8
Make sure that the indoor unit is installed in accordance
with installation dimension instructions (refer to page 5).
9
Do not use the unit in the laundry or by swimming
pool etc.
Installation Site of Outdoor Unit
1
Select a site where noise and outflow air emitted by unit
will not annoy neighbors.
2
Select a site where there is sufficient ventilation.
3
Select a site where there is no obstruction blocking the
inlet and outlet.
4
The site should be able to withstand the full weight
and vibration of the unit.
5
Select a dry place, but do not expose the unit to direct
sunlight or strong wind.
6
Make sure that the outdoor unit is installed in accordance
with the installation instructions, and is convenient for
maintenance and repair.
7
The height difference between indoor and outdoor units
complies with the table on page 8.
8
Select a place where it is out of reach of children.
4 Notice for installation Kelvinator Air Conditioning
Safety Precautions for Electric Appliances
1
A dedicated power supply circuit should be used for
products not supplied with a service cord and plug in
accordance with local electrical safety regulations.
3
The unit must be reliably earthed and connected to
the special earth device by the qualified electrician.
4
The circuit breaker must have the functions of magnetic
tripping and heat tripping to prevent short circuit
and overload.
5
The appliance shall be installed in accordance with
national wiring regulations.
6
Including an circuit breaker with suitable capacity, please
note the following table.
Model
Circuit Breaker (Amps)
KSV26CRC
10
KSV26HRC
10
KSV35CRC
10
KSV35HRC
10
15
KSV53HRC
15
KSV62HRC
20
KSV70CRC
KSV70HRC
20
KSV80HRC
20
Note:
Make sure the live wire, neutral wire and earth wire in
the power socket are properly connected.
Inadequate or incorrect electrical connections may cause
electric shock or fire.
Earthing Requirements
1
Air conditioner is type I electric appliance. Please ensure
the unit is reliably earthed.
2
The yellow-green wire in air conditioner is the earthing
wire which can not be used for other purposes. Improper
earthing may cause electric shock.
3
The earth resistance should accord to the national
wiring regulation.
4
The user's power must have reliable earthing terminal.
Do not connect the earthing wire with the following:
1. Water pipe
2. Gas pipe
3. Contamination pipe

Installation drawing

Space to the ceiling
15cm
Above
15cm Above
Space to the wall
300cm
Above
Air outlet side
The dimensions of the minimum in between
space necessary for properinstallation of the
unit include the minimumpermissible distances
to adjacent parts.
Space to the wall
Air outlet side
If these dimensions are not adhered to the air conditioner will
not perform to specification, may not be able to be serviced
and the warranty may be voided.
the installation must allow for reasonable access
Space to the wall
15cm Above
200
cm
Above
Space to the floor
Space to the obstruction
Air inlet side
Space to the wall
Kelvinator Air Conditioning installation drawing 5

Advertisement

loading