SIS Control

The MLC can be remotely controlled via a host computer or other control device that
is attached to the MLC rear panel Host/Config port. You can issue Simple Instruction
Set (SIS) commands to the MLC via the RS-232 or USB interface of your computer or
control device with a communication software program such as Extron DataViewer or
HyperTerminal. This section contains a list of the SIS commands available for the MLC and
describes procedures for issuing them. The following topics are covered:

Host-to-Controller Communications

SIS commands consist of strings of one or more characters per field. No special
characters are required to begin or end a command sequence. When the MLC determines
that a command is valid, it executes the command and sends a response to the host
device.
Most responses from the MLC to the host end with a carriage return and a line feed
(CR/LF = ] ), which signals the end of the response character string.

Controller-initiated Messages

When a local event such as a front panel button press takes place, the MLC responds by
sending a message to the host, indicating what selection was entered. No response is
required from the host.
The MLC sends the following copyright message only when it first powers on.
(c) Copyright 20nn, Extron Electronics, MLC nn, vn.nn, 60-nnnn-nn
where MLC
is the model number.
This message does not appear with a USB connection.

Error Responses

If the MLC is unable to execute a command it receives because the command is invalid
or contains invalid parameters, the controller returns an error response to the host. This
response consists of the letter
feed. The following error response codes can be returned:
E10
E13
E14
E22
Host-to-Controller Communications
Using the Command and Response Table
Command and Response Table for SIS Commands
is the model name, v
nn
E
– Invalid command or parameter
– Invalid value (out of range)
– Not valid for this configuration
– Busy
is the firmware version number and 60-
n.nn
followed by a number and a carriage return with a line
MLC 60 Series MediaLink Controllers • SIS Control
-