Wiring For Ir Control - Medialink MLC 62 IR D User Manual

Table of Contents

Advertisement

Wiring for IR Control

To control devices via infrared (IR) commands from the MLC, connect one or two IR
emitters to the IR/S port (RS models) or the IR port (IR model). The IR and IR/S ports
provide unidirectional IR signal output to control a display, projector, switcher, or other
device such as a DVD player.
You can connect one or two single IR emitters or one dual IR emitter to the IR or IR/S port
to control one or two devices. Because the MLC captive screw plugs have small openings
that accept just one wire per pole, to connect two IR emitters to the MLC insert one
ground wire (black) and one IR signal wire (black with a white stripe) in the MLC 62 IR or
IR/S port. Connect the IR emitters to those wires as shown below.
(–)
Ground
IR Signal
(+)
One Dual IR Emitter
Legend
(–)
(+)
Figure 21.
For IR control, there can be a maximum of 50 feet (15 m) between the IR or IR/S port and
the IR emitters.
Example: Figure 22 shows a single IR emitter connected to the IR/S port of an
MLC 62 RS EU or an MLC 62 RS MK.
MLC RS EU or MK Rear Panel
Figure 22.
MLC 60 Series MediaLink Controllers • Features, Installation, and Operation
IR Signal
(–)
(+)
Ground
Two Single IR Emitters
Black Wire
Black Wire with White Stripe
IR Emitters for the MLC 60 Series
50'
(15 m max.)
Ground
IR Signal
R
Connecting an IR Emitter to the IR/S Port of an MLC 62 RS EU or
RS MK
(+)
(–)
(+)
(–)
IR Emitter
VCR
DVD Player
25