Input frequency:
Mains supply impedance:
Power factor:
Output frequency range:
Resolution:
Overload capability:
Protection against:
Additional protection:
Operating mode:
Regulation and control:
Analogue input / PID input:
Analogue setpoint resolution:
Analogue output:
Setpoint stability:
Motor temperature monitoring:
Ramp times:
Control outputs:
Interface:
Inverter efficiency:
Operating temperature:
Storage/transport temperature:
Ventilation:
Humidity:
Installation height above sea level:
Degree of protection:
Protective separation of circuits:
Electromagnetic compatibility (EMC):
Comment:
MICROMASTER Vector and MIDIMASTER Vector are designed for use worldwide and therefore for wide line supply voltage ranges (1/3-ph. 208 - 240
V AC ±10%; 3-ph. 380 - 500 V AC ±10%; 3-ph. 525 - 575V AC ±15%)
For the voltage data, it should be noted that:
the operating range of the drive inverter lies between the two specified voltage values - e.g. 208 - 240V,
-
-
the ±10% does not represent an operating range but only the range which is provided to absorb brief voltage fluctuations.
G85139-H1751-U529-D1
4/8/99
47 Hz to 63 Hz
> 1% (fit input choke if < 1%)
³ 0.7
0 Hz to 650 Hz
0.01 Hz
200% for 3 s and then 150% for 60 s (related to nominal current)
Inverter overtemperature.
Overvoltage and undervoltage
Against short-circuits and earth/ground faults pull-out protection.
Protection against running with no load (open-circuit)
4 quadrants possible.( Re-generation back into mains not possible ).
Sensorless vector; FCC (Flux Current Control); voltage/frequency curve;
Unipolar: 0 ~ 10 V/ 2 ~ 10 V (recommended potentiometer 4.7 kW)
0 ~ 20 mA/ 4 ~ 20 mA
Bipolar: -10 ~ 0 ~ +10V
10-bit
0 - 20 mA/4 - 20 mA @ 0 - 500W; stability 5%
Analogue < 1%
Digital < 0.02%
PTC input, l
2
t control
0 - 650 s
2 relays 230 V AC / 0.8 A (overvoltage cat.2); 30 V DC / 2 A
WARNING:
External inductive loads must be suppressed
(see section 1.2)
RS485
97%
0
o
C to +50
o
C (MMV), 0
o
C to +40
-40
C to +70
C
o
o
Fan cooling (software controlled)
95% non-condensing
< 1000 m
MMV: IP20 (NEMA 1) (National Electrical Manufacturers' Association)
MDV: IP21 (NEMA 1) and IP56 (NEMA 4/12)
Double insulation or protective screening.
See section 9.3
70
8. SPECIFICATIONS
o
C (MDV)
© Siemens plc 1999