Frame
Voltage
Current
MFLB
Size
Phase
[V]
[A]
(FS)
6SE6400-2FA00-6AD0
A
200 - 480
6
3
6SE6400-2FB00-6AD0
A
200 - 480
6
3
6SE6400-2FL01-0AB0
A
200 - 240
10
1
6SE6400-2FS01-0AB0
A
200 - 240
10
1
6SE6400-2FA01-4BC0
B
200 - 240
14
3
6SE6400-2FB01-4BC0
B
200 - 240
14
3
6SE6400-2FL02-6BB0 *)
B
200 - 240
26
1
6SE6400-2FS02-6BB0
B
200 - 240
26
1
6SE6400-2FS01-6BD0
B
380 - 480
16
3
6SE6400-2FB01-4BC0
B
200 - 480
14
3
6SE6400-2FS03-5CB0
C
200 - 240
35
1
6SE6400-2FS03-8CD0
C
200 - 480
38
3
*) MICROMASTER 4 : The DC+ and DC- marked wires have to be connected to the appropriate terminals of the inverter.
SINAMICS G110
: The DC+ and DC- marked wires are volt-free connections and can be taped up, or cut off.
Issue A7
F
FSB
FSC
Gland Plate
(optional)
W
e
g i
t h
O
v
e
a r
l l
i D
m
e
n
s
o i
n
s
(
m
m
)
Filter
Filter
Filter + Inverter
Inverter
kg
A
B
C
D
E
F
G
H
0.5
0.5
200
73
43.5
200
73
192.5
160
0.5
0.5
1
1
1
213
149
50.5
213
149
222.5
138
174
1
1
1
1.5
245
185
55
245
185
250
174
204
1.5
MICROMASTER 4
K
E
L
H
D
FSB
FSC
F
x i
n i
g
i D
m
e
n
s
o i
n
s
(
m
m
)
Terminals
Cable Cross Section
Tightening
Filter
min
Torque
Footprint
Side Mount
Fixing
Fixing
2
Nm
lbf.in mm
AWG mm
Size
Size
I
J
K
L
Foot-
print:
M5 (4)
M4 (2)
56
187
187
1.1
5 - 7
1
Side
Mount:
M5 (2)
M4 (4)
120
200
24
200 M5 (4)
1.5
13.3
1.5
M4 (4)
156
232
38
232 M5 (4)
2.25
20
2.5
I
FSB
G
FSC
J
I
May also be used with CT and VT rated inverters when
specified in the MICROMASTER Catalog DA51.2.
L
J
H
May also be used with inverters when specified in the
FSA
SINAMICS Catalog D11.1.
1
max
2
AWG
17
2.5
14
16
6
10
2
14
10
8
Frame Size A to C
Ground
2
CT
VT
Catalog DA 51.2
HO
LO
Catalog D 11.1
Ground
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MICROMASTER 4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Siemens MICROMASTER 4

  • Page 1 6SE6400-2FS03-8CD0 200 - 480 *) MICROMASTER 4 : The DC+ and DC- marked wires have to be connected to the appropriate terminals of the inverter. SINAMICS G110 : The DC+ and DC- marked wires are volt-free connections and can be taped up, or cut off.
  • Page 2 OPTIONS COMBINATIONS EXAMPLES MAINS INPUT MAINS INPUT OUTPUT CHOKE INPUT CHOKE (REVERSED) FILTER FILTER FILTER MOTOR CABLE MAINS FILTER CABLE FILTER CABLE FILTER CABLE OUTPUT CHOKE CABLE INPUT CHOKE CABLE INPUT CHOKE OUTPUT (REVERSED) CHOKE Recommended Combinations Inverter Footprint Mounted on side Example Frame Size Position 1 Position 2 Line-side...

Table of Contents