How to Loosen ( 2 )

The maximum loosening torque for [ Ind ] mode is 800 Nm.
① Turn the Reverse Lever to the left.
L : Reverse direction
( Loosening the right handed screw)
② Apply the reaction force absorber next to the fastening bolt/nut.
And press the throttle lever.
While loosening, [ - L - ] will be displayed.
If exceeding the maximum torque 800 Nm,
displayed and the torque limiter will shut off the machine.
In this case, please use an impact wrench to loosen the bolt/nut.
Warning
・ While operating PTS, do not touch the reaction force absorber or the socket.
・ If something wrong with PTS, please release the throttle button and stop the
operation.
Industrial Mode [Ind]
will be
Reverse Lever
Lights

Advertisement