Table of Contents

Advertisement

Nice
0682
EN50131 Grade 1
HSCU1
Home security control unit
EN - Instructions and warnings for installation and use

Advertisement

Table of Contents
loading

Summary of Contents for Nice HSCU1

  • Page 1 Nice 0682 EN50131 Grade 1 HSCU1 Home security control unit EN - Instructions and warnings for installation and use...
  • Page 2: Ec Declaration Of Conformity

    Declaration in compliance with Directive 1999/5/EC Note – The content of this declaration corresponds to that specified in the official document deposited at the Nice S.p.A. headquarters and, in particular, to the latest revised edition available prior to the publishing of this manual. The text herein has been re-edited for editorial purposes. A copy of the original declaration can be requested from Nice S.p.A.
  • Page 3: Table Of Contents

    HSCU1G - HSCU1) ........
  • Page 4: Established Legislation, Warnings And General Precautions

    GSM/GPRS module HSCU1: primary alkaline battery power, no 230V mains power – no GSM/ GPRS module IMPORTANT: this manual covers the features of the most complete model,...
  • Page 5: Designing An Alarm System

    DESIGNING AN ALARM SYSTEM In order to obtain an alarm system which is perfectly functional and suited to floor area to group B and the garages to group C. This division enables one, the task in question, the installation must be designed in advance, before pro- for instance, to activate the garage alarm (group C) while using the rest of the ceeding with the operations described in this manual.
  • Page 6 In small apartments or in densely inhabited areas, an outdoors siren may not HSDIM10 HSDIW01 HSDIM12 HSDID11 HSDIM23 HSCU1GC HSCU1C HSDIM24 HSCU1G HSCU1 HSDIM12 HSDID11 HSDIW01 HSDIM12 HSDIM10 HSDIS01 HSSI HSDID11 HSSO1 HSDID11...
  • Page 7 TABLE 1 Door sensor: an intrusion detector designed for use on doors and windows which reports the opening of the door or window when its magnet is moved away from its body. The detector is generally installed to the fixed part of the door or window, opposite to the hinges, with the magnet attached to the mobile panel.
  • Page 8: Elements Of The Nice Home Security Alarm System

    3.3 - Elements of the Nice Home Security alarm system Control panel EN50131 Grade 1 The control panel controls the system itself; it receives information from the detectors, keyboards and transmitters, and trips the siren or sends messages over the landline or cellular network as appropriate. It has an integral siren which sounds when an intrusion is detected.
  • Page 9 HSSI Actuators The Nice Home Security alarm system is not only a home alarm system, but can also interact with domotics appliances. A series of special actuators will operate other devices like lights, open gates, shutters, and so on. The following models are available:...
  • Page 10: Installation: Control Panel And Accessories

    • Install the control panel at least 1 m off the ground. • the product may only be used with Nice Home Security system devices. 4.3 - Description of the control panel All control panel models have a system memory card with voice guide (“l”...
  • Page 11: Installation Control Panel

    4.4 - INSTALLATION: Control panel • For models HSCU1GC and HSCU1C: (models HSCU1GC - HSCU1C and HSCU1G - HSCU1) make the electrical connections and insert the backup battery with refer- ence to chapter chapter 5. Caution - Before proceeding with the installation, read par. 4.1 - 4.2 - 4.3.
  • Page 13 HSCU1G and HSCU1...
  • Page 14: Electrical Connections

    ELECTRICAL CONNECTIONS 5.1 - Important warnings • The mains power hookup must be done by a qualified electrician in line with electrical equipment regulations. • Install a 2-pole circuit breaker with contact gap of at least 3 mm, or an elec- trical cable equipped with a plug for a standard socket.
  • Page 15 HSCU1GC / HSCU1C HSCU1GC / HSCU1C +12V +OFF +SIR +SAA 24H GND +OFF +SIR +SAA 24H GND TAMPER ALARM SIR GND BATTERY BATTERY BATT BATT TAMP TAMP HSSOC HSSOC HSCU1GC / HSCU1C +OFF +SIR +SAA 24H GND BATTERY BATT TAMP HSSOC LINE NC1 C1...
  • Page 16: Programming The Control Panel

    PROGRAMMING THE CONTROL PANEL MEANING AND USE OF FUNCTION KEYS CONFIRM REQUEST CONFIRM QUIT DISARMING SIM CREDIT SCROLL MENU DELETE DELETE CONFIRM REQUEST CANCEL CHARACTER ARMING TELE-SERVICE TABLE 3 SITUATION OF CONTROL PANEL WHEN FIRST POWERED UP proceed by pressing OK then scroll through the options and confirm MEMORY REMOTE CONTROLS DETECTORS'ISOL.
  • Page 17 (< -10°C or > Caution! NICE is not responsible for changes made by the cellular 55°C), PSTN phone line fault. operator which may make any of the functions, set up with the informa- FREE FIELDS –...
  • Page 18 IMPULSIVE: switches for 0 to 999 seconds on receiving an internal Models HSCU1G and HSCU1: the units are factory set for backlighting clock or phone command. to go out after 60 seconds idle time.
  • Page 19: Digital Protocols

    is always manual. Example CESA 200 BAUD: After you enter the event ALL ( OK ), the position 6.2.35 - ARMING BLOCK: This function is always active if EN50131 is set to CODEV1 A03 ( OK ), the first line proposes the code to asso- Y (6.2.36).
  • Page 20 GROUP C WIRED TAMPER 1 137 03 000 1 12 24H PANIC AL. GROUP TAMPER 1 137 04 001/099 1 12 24H ROBB. AL. GROUP TAMPER 1 137 05 001/009 1 12 24H TECHN. AL. GROUP TAMPER 1 137 06 001/009 1 12 ARMING VIA USER CODE 1 401 00 000...
  • Page 21: Programming Alarm Systems / Wireless Warning

    PRODUCT MAINTENANCE 7.1 - Replacing the batteries (control panel and accessories) In general, Nice Home Security products do not require special maintenance; however, they should be kept clean, especially the detectors, whose sensors When the battery (battery pack or backup battery) of the control panel or the must be kept clean of dust and other dirt (refer to the respective user manuals).
  • Page 22 HSCU1GC and HSCU1C only models HSCU1G and HSCU1 only...
  • Page 23: What To Do If

    AND Wait for at least 3 minutes and try again. function. • All Nice Home Security system products • A detector occasionally generates false tampering alarms Nearly all products are protected against opening and removal; the areas of This may be due to temperature differentials deforming its housing surface.
  • Page 24: User Manual

    USER MANUAL 9.1 - ACCESS CODES – Caution! If you enter an invalid code 5 phone transmission to the phone book numbers when the times in a row, the keyboard locks up for 3 minutes! corresponding events are detected. 2 access codes are required to work on the control panel, each from 9.4.2 - EXTRAS: 4 to 8 digits: the USER code and the INSTALLER code.
  • Page 25: User Access For Operation (Table 2)

    cally activates the service. The control panel is rearmed when 9.5.1.1 - CONTROL PANEL TEST Enter the user or installer code and press . Select Control Panel with and press the connection with the service centre is dropped. Caution! OK. Procedure: Try the remote controls and trip the alarms of This code may not be the same as the user code: see 6.3.4.
  • Page 26 has the following meaning: WIRELESS SIREN TEST: press to sound the siren if the connection is correct. C1 433 MHz signal: excellent (*) 9.5.1.2 - DIALLER and GPRS TEST: Enter the user or C2 868 MHz signal: very good (*) installer code and press .
  • Page 27: Access For Manoeuvres - Arming/Disarming The Control Panel

    9.6 - ACCESS FOR MANOEUVRES - ARMING/DISARMING THE 9.7 - ALARM FUNCTIONS CONTROL PANEL In case of an alarm, the control panels activate the internal (removable) The control panel has 3 intrusion alarm groups which can be armed in siren, the local alarm devices (sirens and other dissuaders) and make any combination, depending on system configuration and the user's calls on the landline and cellular phone lines, as follows requirements.
  • Page 28: User Remote Control - Domotic Functions (Uncertified Characteristics)

    - see 6.2.7. You can also obtain remaining credit information remotely from TIM-WIND-VODAFONE, by sending Nice is available for information and support, but is not liable for the an SMS to the control panel consisting of a single question...
  • Page 29: User Information

    Alternatively, a HSA2 card for extending the phone line inwards 10.5 - ELECTRONICS COMMON TO BOTH CONTROL UITS • all cables required to install wired peripherals, connected to the main The 3015 (HSCU1G) - 30152 (HSCU1) electronics cards are connect- terminal block. ed to: The unit has a slot for a removable non-volatile EEprom, can be used •...
  • Page 30 factory coded digital codes self-learnt by microprocessor - legally compliant frequency and power Wireless range: 100m free range without background disturbance on band - wireless range may be considerably reduced in interiors, partly due to the location of the devices relative to the building struc- tures.
  • Page 31: Quick Programming Guide

    - To scroll through the menus, use p q. - Press OK to select options. - To select groups A, B and C, use the numeric keys 1 to 6. COMPLETE MENU OF HSCU1 CONTROL PANELS Warnings: - The INSTALLER CODE accesses all menus.
  • Page 32 Nice SpA Oderzo TV Italy www.niceforyou.com info@niceforyou.com...

Table of Contents