3.3 - Elements of the Nice Home Security alarm system

Control panel
The control panel controls the system itself; it receives information from the detectors, keyboards and transmitters,
and trips the siren or sends messages over the landline or cellular network as appropriate. It has an integral siren
which sounds when an intrusion is detected. The integrated keyboard is used for configuration and can also be
used as an internal control device. The control panel is equipped with phone diallers which connect the protected
area to the outside world, even over large distances. If an alarm is tripped, ti automatically sends a message to the
phone numbers programmed into it: owner, police, etc. The GSM version can also send SMS's.
The reverse function can also be enabled: this allows you to send commands to the control panel with a telephone
call.
The following models are available:
HSCU1GC
Control panel for hybrid wired/wireless alarm systems, 230 V AC mains powered. Equipped with PSTN and GSM phone dialler
HSCU1C
Control panel for hybrid wired/wireless alarm systems, 230V AC mains powered. Equipped with PSTN phone dialler
HSCU1G
Control panel for wireless alarm systems, battery powered. Equipped with PSTN and GSM phone dialler
HSCU1
Control panel for wireless alarm systems, battery powered. Equipped with PSTN phone dialler
Detectors
Detectors control property and the rooms in which the property is located, and transmit their status to the control panel. To operate effectively, they must be
located at the strategic points of rooms, doors, windows, shutters, porticoes and so on. Detectors can be divided into:
- perimeter detectors for the opening of doors, windows and shutters
- perimeter detectors, using vertical shutter detectors
- volumetric detectors, for detecting the presence of intruders within their area of coverage
- dual technology detectors, combined IR and microwave units.
- outdoors detectors, for protecting outdoors areas, porticoes, verandas, gardens and so on.
- special detectors, for detecting flooding, smoke, breaking glass, etc..
Up to 99 detectors can be connected to the control unit wirelessly, or double the number if installed in pairs with the AND function. Wired connection control
panels have 6 inputs for wired detectors, which can be assigned freely to groups A, B and C.
The following models are available:
HSDID11
Magnetic contact detector; one NO and one NC input (including pulse count); single or differentiated alarm. Break-in sensor
HSDIM10
IR detector with volumetric lens with input for second contact (NC or pulse count); single or differentiated alarm. Break-in sensor
HSDIM12
IR detector with shutter lens with input for second contact (NC or pulse count); single or differentiated alarm. Break-in sensor
HSDIM23
IR detector with volumetric lens for indoors use, coverage up to 12m with 120° field of view. With sensitivity adjustment, alarm trips
immediately or on second pulse, tamperproof (opening and removal).
HSDIM24
Dual technology volumetric detector (IR and microwave radar), for indoors use, coverage up to 12m with 90° field of view. With sensitivity
adjustment, alarm trips immediately or on second pulse, tamperproof (opening and removal) and anti-blinding function.
HSDOM21
Dual technology volumetric detector (IR and microwave radar), for outdoors use, coverage up to 12m with 90° field of view. With sensitivity
adjustment, alarm trips immediately or on second pulse, tamperproof (opening and removal) and anti-blinding function.
HSDID01
Volumetric glass breakage detector
HSDIS01
Combustion smoke detector (volatile fine particles)
HSDIW01
Flooding detector
EN50131 Grade 1
HSDID11
HSDIM10
HSDIM12
Transmitters
These are the simplest and most practical solution for arming or disarming the alarm system, whether from inside or
outside the protected area; allows the user to arm the entire system or part thereof, as well as sending emergency
signals.
The following models are available:
HSTX4
Two way 4 channel alarm system transmitter
HSTX8
Two way 8 channel transmitter, 4 channels for alarm systems and 4 channels for automation
control signals
6
HSDIM23
HSDIM24
HSDOM21
HSDOM22
HSDID01
HSDIS01
HSTX8
EN50131
Grade 1
HSCU1GC
HSCU1C
HSCU1G
HSCU1
HSDIW01
HSTX4