Advertisement
MNS: alarm siren via radio for outdoor applications with integrated warning light for the MyNice system.
:
The control unit in configuration mode automatically detects the device once the batteries are inserted. Prior to inserting the batteries, read the MyNice instruction manual and follow the control unit instructions on the monitor.
Batteries – 6 X LR20 1,5V (supplied). Only replace the batteries when the detector and control unit signal the need. Before performing this operation, access the device configuration menu on the control unit (test mode).
Extract the box from the siren bottom without disconnecting the wires, remove the cap from the microphone and use the TAMPER button as explained below.
To listen to a message again, press the tamper button for 2 seconds. Once the message has been heard, the system returns to Point 3
Message | Status | LED | LED colour | Duration |
Pre-alarm | absent | flashes | orange | 5 sec |
Pre-alarm | present | on | orange | 5 sec |
Alarm 1 | absent | flashes | red | 15 sec |
Alarm 1 | present | on | red | 15 sec |
Alarm 2 | absent | flashes | green | 10 sec |
Alarm 2 | present | on | green | 10 sec |
Do not bend the antennas and put the cap back onto the microphone hole
Before proceeding with the installation, position the device near the assembly zone and run the radio range test.
Operation test to be effected when requested by the control unit: siren test.
General alarm: flash, continuous beep
Programmable, excludable/optional functions:
Full engagement: 3 flashes, 3 short beeps
Disengagement: 1 flash, 1 short beep
Pre-alarm: flash, 1-sec intermittent beep
Vocal alarms 1 and 2: flash, vocal message or 3-sec intermittent beep
Technical alarm: flash, vocal message or 5-sec intermittent beep
Maintenance: 2.5-sec intermittent beep
MNS | TECHNICAL SPECIFICATIONS |
6 x LR 20 1,5 V (16 Ah) | Power supply |
< 360 μA | Current draw at rest |
< 660 mA | Current draw during operation |
> 4 | Battery life years - roughly * |
18' | Supervision |
GFSK Dual Band MHz 433,54-433,92; MHz 868,30-868,94 | Radio transmission double frequency |
> 100 m | Open-field radio range without disturbances ** |
III | Insulation (class) |
2 | Environmental class n accordance with EN 50131 |
-25°C... +55°C | Operating temperature |
250 x 85 x 250 mm | Dimensions (WxDxH) |
2250 g | Weight |
35 | IP |
The above characteristics refer to an ambient temperature of 20°C (± 5°C) and to normal use of the device in a residential setting.
*
The battery life refers to normal use of the device.
**
RF interferences and the position of the devices in buildings can reduce the radio range.
Opening of the devices, with the exception of the battery compartment, implies the immediate voiding of the industrial warranty.
Nice S.p. A. declines all liability for damages resulting from improper use of the product, other than as specified in this manual.
In order to improve its products, Nice S.p. A. reserves the right to modify their technical specifications at any time without prior notice, without however altering their functions or intended use.
The battery must be disposed of in the appropriate bins according to current regulations; when scrapping the device, the battery must be removed beforehand.
Hereby, NICE S.p. A., declares that the radio equipment type
- MNS
is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.niceforyou.com/en/support
Nice S.p. A.
Via Pezza Alta, 13
31046 Oderzo TV Italy
info@niceforyou.com
www.niceforyou.com