factory coded digital codes self-learnt by microprocessor - legally
compliant frequency and power
Wireless range: 100m free range without background disturbance
on band - wireless range may be considerably reduced in interiors,
partly due to the location of the devices relative to the building struc-
tures.
Wired connection: PSTN phone line (ADSL as well with suitable fil-
ters)
Phone section: see chapter 10.7
Dimensions: 307 x 200 x 53mm
Weight: 2.4 kg
Enclosure: ByBlend
Temperature: operating/storage -10° to +40°C
10.7 - INTEGRAL PHONE TRANSMITTERS - SPECIFICATIONS
All control panels have a PSTN phone transmitter (landline) compliant
with ETSI ES 203-21 & RTTE using the ATS 1 transmission system
and emissions per EN 61000-6-3. The operating time is 12 seconds
for voice transmissions and 19 seconds for Contact-Id digital trans-
missions. For the functional aspects, see chapter 6, 9.
The HSCU1GC and HSCU1G units also have a GSM transmitter,
compliant with ETSI ES 203-21 & RTTE with ATS1 transmission sys-
tem and emissions per EN 61000-6-3. The operating time is 14 sec-
onds for voice transmissions and 14 seconds for Contact-Id digital
transmissions. For the functional aspects, see chapter 6.3.
For programming the numbers, messages and their characteristics,
see chapters 6.2.1 to 6.2.7.
Caution! - In model HSCU1G the GSM module is normally off to save
power: it turns on and connects to the GSM network when an alarm is
generated. The time taken to do this does not depend on the device
and varies according to location, and must be added to the above
timings.
10.7.1 - PSTN CONNECTION: the outside phone line must enter the
control panel directly without intervening equipment, and be
connected via the provided connector. If card HSA2 is added,
the outside line must be connected to the input terminals and
the equipment downline of the control panel to the output
terminals.
10.7.2 - INTEGRAL GSM MODULE: manufacturer: Telit code
GE864QuadV2 compliant with ETSI ES 203-21 and RTTE
with ATS 2 transmission system and emissions per EN 61000-
6-3. The operating time is 12 seconds for voice transmissions
and 10 seconds for Contact-Id digital transmissions.