Ensuring Proper Ventilation - HP Z228 Maintenance And Service Manual

Table of Contents

Advertisement

Ensuring proper ventilation

Proper ventilation for the system is important for workstation operation. Follow these guidelines:
Operate the workstation on a sturdy, level surface.
Provide at least 15.24 cm (6 inches) of clearance at the front and back of the workstation. (Workstation
models vary.)
Be sure that the ambient air temperature falls within the environmental specifications listed in this
document.
NOTE:
1°C (33.8°F) per 304.8 m (1000 ft) derating above 1524 m (5000 ft). So, at 3,048 m (10,000 ft), the
upper ambient air temperature limit is 30°C (86°F).
For cabinet installation, be sure that adequate cabinet ventilation and the ambient temperature within
the cabinet does not exceed specified limits.
Never restrict the incoming or outgoing airflow of the workstation by blocking any vents or air intakes,
as shown in the following figure.
8
Chapter 1 Hardware overview
The ambient upper limit of 35°C (95°F) is only good up to 1524 m (5000 ft) elevation. There is a

Advertisement

Table of Contents
loading

Table of Contents