Adjusting The Cutting Unit Flow Control - Toro 30410 Operator's Manual

Traction unit
Hide thumbs Also See for 30410:
Table of Contents

Advertisement

Figure 75
1. Test port E
Test Port F (Figure 76), located under the seat, is used
to measure the lift circuit pressure.
Test Port G (Figure 76), located under the seat, is used
to measure the charge circuit pressure.
Figure 76
1. Test port F
Test Port H (Figure 77) is used to measure the front
cutting unit circuit pressure.
Test Port J (Figure 77) is used to measure the steering
circuit pressure.
2. Test port G
1. Test port I
The counterbalance test port (Figure 78) is used
to adjust the pressure in the counterbalance circuit.
Recommended counterbalance pressure is 470 psi (3241
kPa). To adjust the counterbalance pressure, rotate the
adjusting screw (Figure 78) clockwise to increase the
pressure or counterclockwise to decrease the pressure.
1. Counterbalance test port
Adjusting the Cutting Unit
Flow Control
The flow control valve (Figure 79) is used to adjust the
rate at which the front cutting unit lowers.
1. Flow control valve
49
Figure 77
2. Test port H
Figure 78
2. Counterbalance adjusting
screw
Figure 79

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 4000-d30410te

Table of Contents